某地下室上浮事故的检测鉴定及加固处理 被引量:19

TEST APPRAISAL AND REINFORCEMENT OF A FLOATED BASEMENT
原文传递
导出
摘要 深圳某建筑地下室受到地下水浮力作用产生不均匀上浮,最大上浮量达到397 mm,导致地下室结构损伤严重。通过对受损结构检测,分析上浮原因及结构破坏机理,在此基础上对地下室结构进行永久抗浮处理和结构加固处理,取得了良好的经济和社会效益。 In Shenzhen a building’s basement rose up unevenly because of groundwater buoyancy force action,the maximum rising was up to 397 mm,which caused serious damage to structural components.In this paper,the floated reason of the basement and the failure mechanism of the structure were analyzed,and on this basis,the completed permanent anti-buoyant treatment and the structure reinforcement of the basement were carried out,which achieved good economic and social benefits.
出处 《工业建筑》 CSCD 北大核心 2010年第6期127-130,共4页 Industrial Construction
关键词 地下室 损伤 抗浮 加固 basement damage anti-buoyant reinforcement
  • 相关文献

参考文献6

二级参考文献5

  • 1贾金青.软岩抗浮锚杆试验、设计及施工[M].北京:人民交通出版社,2000..
  • 2中国工程建设标准化协会.土层锚杆设计与施工规范[M].,1991..
  • 3CECS22:90.土层锚杆设计与施工规范.[S].,..
  • 4贾金青.复杂地层深基坑支护的方法与实践[J].岩土锚固工程,2000,(2).
  • 5《岩土工程锚固技术》编审委员会.岩土工程锚固技术.北京:人民交通出版社,1996.