期刊文献+

MRC装置冷剂量改变时系统动态特性的仿真模型 被引量:1

Dynamic simulation model of MRC plant with refrigerant charged or leaked
下载PDF
导出
摘要 向混合制冷剂循环(MRC,Mixture Refrigerant Cycle)装置中充注冷剂或冷剂发生泄漏或排放,会改变装置的运行工况。对此规律的研究与掌握,对装置的设计和操作运行有重要的指导意义。基于工艺模拟、质量守恒及装置的内在工作特性,建立了能对这一动态特性进行模拟的数学模型,并针对一简单的SMR流程对充注C1、C5冷剂时系统运行工况的变化进行了模拟研究。 The running condition of a MRC plant will be affected by the charge or leakage of the refrigerant. It is significant for the design and operation of the plant. A new model based on the process simulation, mass conservation and characteristics of the system was established to study the dynamic performance in these cases. The change of system condition for charge of C1 and C 5 was investigated.
出处 《低温与超导》 CAS CSCD 北大核心 2010年第6期7-9,20,共4页 Cryogenics and Superconductivity
基金 2008年度"高等学校博士学科点专项科研基金"新教师课题"新型MRC-低温分馏法含氧煤层气液化工艺研究"(200804251006)资助
关键词 MRC 冷剂 组分 充注 MRC, Refrigerant, Composition, Charge
  • 相关文献

参考文献8

二级参考文献32

共引文献89

同被引文献9

  • 1REMELJEJA C W, HOADLEY A F A. An exergy analy- sis of small-scale liquefied natural gas (LNG) liquefac- tion processes [J]. Energy,2006, 31( 12):2005-2019.
  • 2王保庆.天然气液化工艺技术比较分析[J].天然气上业,2009,29(1):111—113.
  • 3LIN W S, ZHANG N, GU A Z. LNG (liquefied naturalgas): a necessary part in China's future energy infra- structure[J]. Energy, 2010, 35( 11 ) :4383-4391.
  • 4ALABDULKAREM A, MORTAZAVI A, HWANG Y, et al. Optimization of propane pre-cooled mixed refriger- ant LNG plant [ J 1. Applied Thermal Engineering, 2011 (31) : 1091-1098.
  • 5ASPELUND A, GUNDERSEN T, MYKLEBUST J,et al. An optimization-simulation model for a simple LNG process [ J]. Computers & Chemical Engineering, 2010, 34(10) : 1606-1617.
  • 6J~RGEN B J, SIGURD S. Single-cycle mixed-fluid LNG process. Part I ~ Optimal design [ C ]//Proceedings of the 1st Annual Gas Processing Symposium. Doha, Qatar: Elsevier, 2009: 211-214.
  • 7J~RGEN B J, SIGURD S. Single-cycle mixed-fluid LNG process. Part l]. Optimal operation [ C ]//Proceedings of the 1st Annual Gas Processing Symposium. Doha,Qatar: Elsevier, 2009 : 215-218.
  • 8ARJUN S, MORTEN H. Model requirement for control design of an LNG process [ Jl. Computer Aided Chemical Engineering, 2007, 24: 533-538.
  • 9HATCHER P,KHALILPOUR R,ABBAS A. Optimisation of LNG mixed-refrigerant process considering operation and design objectives[ J]. Computers and Chemical Engi- neering, 2012, 41 : 123-133.

引证文献1