经皮冠状动脉介入治疗中患者受照剂量调查 被引量:4

Survey on the dose of patients in percutaneous coronary intervention
原文传递
导出
摘要 目的调查经皮冠状动脉介入治疗中患者受照的辐射剂量。方法选取1家省级医院进行现场调查并记录相关数据,根据收集的数据进行体模实验。结果胸部的体表剂量最高(1.89×10-5~1.18×10-2C/kg);吸收剂量最大的器官或组织为肾上腺(1.22×10-1Gy),性腺(5.22×10-6Gy)的吸收剂量最小;有效剂量为1.43×10-2Sv。结论经皮冠状动脉介入治疗的患者受照剂量明显偏高,且多集中在照射野周围,对距离操作部位较近的重要器官应采取必要的防护措施。 Objective To investigate the dose of patients in percutaneous coronary intervention.Methods A phantom experiment was carried out based on the data investigated and collected in a provincial hospital.Results The maximum surface dose was found in the chest (1.89×10-5~1.18×10-2 C/kg).The maximum absorbed dose of the organ or tissue was the adrenal (1.22×10-1 Gy),while the absorbed dose of gonad (5.22×10-6 Gy) was the smallest in all organs.The effective dose in this experiment was 1.43×10-2 Sv.Conclusion The dose of the patient were obviously high in percutaneous coronary intervention,especially in radiation field.The organs close to the operation site should be protected by necessary measures.
出处 《中国职业医学》 CAS 北大核心 2010年第3期208-210,共3页 China Occupational Medicine
基金 中国职业卫生标准项目(2005GG3208041)
关键词 经皮冠状动脉介入治疗 介入放射学 患者 剂量 Percutaneous coronary intervention Interventional radiology Patient Does
  • 相关文献

参考文献9

  • 1No authors listed. The 2007 recommendations of the international commission on radiological protection. ICRP publication 103 [ J]. Ann ICRP,2007,37 (2/4) : 1 - 332.
  • 2PAPAGEORGIOU E, TSAPAKI V, TSALAFOUTAS I A, et al. Comparison of patient doses in interventional radiology procedures performed in two large hospitals in Greece [ J ]. Radiat Plot Dosimetry, 2007,124(2) :97 - 102.
  • 3KOENIG T R, WOLFF D, METTLER F A, et al. Skin injuries from fluoroscopicaily guided procedures: part I, characteristics of radiation injury[ J]. AJR Am Roentgenol,2001,177 ( 1 ) :3 - 11.
  • 4WENZL T, MCDONALD J C. Is there an elevated risk of brain cancer among physicians performing interventional radiology procedures? [J]. Radiat Prot Dosimetry,2002,102(2):99-100.
  • 5苏首勋,刘红卫.介入诊疗的个体防护效果探讨[J].中国职业医学,2007,34(3):248-249. 被引量:2
  • 6STRANDEN E, WOHNI T. The new ICRP concept of person dose related to exposure for radiation qualities used in industrial radiography [J]. Health Phys,I978,35(3) :457 -460.
  • 7MCPARLAND B J. A study of patient radiation doses in interventional radiological procedures [ J ]. Br J Radiol, 1998,71 ( 842 ) : 175 - 185.
  • 8肖锋,徐国千,涂彧,周菊英,刘一之.肝脏介入操作所致患者辐射剂量的初步研究[J].苏州大学学报(医学版),2005,25(3):405-408. 被引量:9
  • 9PEPdSINAKIS K, DAMILAKIS J, THEOCHAROPOULOS N, et al. Accurate assessment of patient effective radiation dose and associated detriment risk from radiofrequency catheter ablation procedures [ J]. Circulation ,2001,104 ( 1 ) :58 - 62.

二级参考文献7

  • 1侯金鹏,邓大平,宗西源,孙作忠,杨迎晓,王燕南.X射线CT检查中病人剂量测试与评价[J].中国辐射卫生,1995,4(3):178-180. 被引量:7
  • 2Larkin CJ, Workman A, Wright RE, et al. Radiation doses to patients during ERCP [J]. Gastrointestinal Endoscopy, 2001,53(2):161-164.
  • 3Xu T, Le HQ, Molloi S. Patient-specific region-of-interest fluoroscopy device for X-ray dose reduction[J]. Radiology, 2003, 226(2):585-592.
  • 4Miller DL, Baiter S, Cole PE, et al. Radiation doses in interventlonal radiology procedures: the RAD-IR study: Part Ⅱ:skin dose[J]. Journal of Vascular & Interventional Radiology, 2003,14(8):977-990.
  • 5Valentin J. Avoidance of radiation injuries from medical interventional procedures [J]. Annals of the ICRP,2000, 30(2):53-57.
  • 6国家质量监督检验检疫局.GBZ130-2002 X射线诊断卫生防护标准[S].北京:中国标准出版社,2002.
  • 7侯金鹏,邓大平,朱建国,陈玉祥,孙秀兰,冯宪勋,李占来,陆鸿.介入放射学工作者剂量估算方法探讨[J].中国辐射卫生,1998,7(4):210-212. 被引量:11

共引文献9

同被引文献52

  • 1徐国千,涂彧,肖锋,万骏,刘犁,周菊英,刘一之.介入放射学诊疗中患者所受辐射剂量调查研究[J].辐射防护,2006,26(3):172-176. 被引量:8
  • 2李雅春,杜国生,马永忠,孔玉霞,王树华,王金龙,董利伟,胡灏.155例介入放射学受检者剂量调查[J].中国辐射卫生,2007,16(1):51-53. 被引量:17
  • 3白玫,刘彬,郑钧正.心脏介入患者受照剂量研究[J].介入放射学杂志,2007,16(4):222-225. 被引量:14
  • 4白玫,刘彬,郑钧正,彭明辰.两种介入放射学(CA和PTCA)所致患者辐射剂量研究[J].中国医学影像技术,2007,23(12):1876-1881. 被引量:23
  • 5ICRP. Avoidance of radiation injuries from medical interventional procedures[ R]. ICRP Publication 85, Oxford: Pergamon press, 2001.
  • 6Lawrence T. Dauer, Raymond Thomton, Daniel C. Boylan, et al. Organ and effective dose estimates for patients undergoing hepatic arterial embolization for treatment of liver[ J]. Med Phys, 2011, 38(2) :736 -742.
  • 7Gaetano Compagnone, Emanuela Giampalma, Sara Domenichelli, et al. Calculation of conversion factors for effective dose for various interventional radiology procedures [ J ]. Med. Phys. 2012, 39 (5) :2491 -2499.
  • 8Maria Daniela Falco, Marco D Andrea, Lidia Strigari, et al. Char- acterization of a cable - free system based on p - type MOSFET de- tectors for "in vivo" entrance skin dose measurements in interven- tional radiology[ J]. Med Phys, 2012,39 (8) :4866 - 4875.
  • 9Cecline Bassinet, Christelle Huet, Marion Baumann, et al. Char- acterization of MOSFET detectors for in vivo dosimetry in interven- tional radiology and for dose reconstruction in case of overexposure [ J J. Health Physics, 2013,104 (4) :379 - 385.
  • 10Schuhz FW, Zoetelief J. Dose conversion coefficients for interven- tional procedures [ J ]. Radiation Protection Dosimetry, 2005 (117) :225 -230.

引证文献4

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部