期刊文献+

有晶状体眼后房型人工晶状体植入术治疗高度近视的临床研究

Clinical research of phakic posterior chamber intraocular lens implantation for high myopia
原文传递
导出
摘要 目的 探讨有晶状体眼后房型人工晶状体(ICL)植入术治疗高度近视的临床效果.方法 对12例24眼接受ICL植入术的患者资料进行总结和分析,比较其手术前后最佳矫正视力、眼压及透明晶状体性状的改变.结果 12例24眼术后最佳矫正视力均达到或超过术前最佳矫正视力,改善了高度近视患者的视功能状况,术前眼压(14.26±2.13)mm Hg(1 mmHg=0.133 kPa),术后1年眼压(14.79±2.77)mm Hg(P>0.05),术后眼压稳定,术后ICL与透明晶状体存在裂隙,随访期间未见并发性白内障、慢性色素膜炎等并发症.结论 ICL植入术治疗高度近视手术效果确切,预测性好,安全性高. Objective To investigate the clinical efficacy and safety of phakic posterior chamber intraocular lens (ICL) implantation for high myopia. Methods Twenty-four eyes of 12 patients with high myopia were treated with ICL implantation. The best corrected visual acuity, intraocular pressure and lens changes shape between post-operative and pre-operative were compared. Results Successful implantations were done in all patients. All eyes had a significant increase in uncorrected visual acuity. Exactly improved visual function in patients with high myopia status. The intraocular pressure was ( 14.26 ± 2.13) mm Hg(1 mm Hg = 0.133 kPa) of pre-operative , and was ( 14.79 ± 2.77) mm Hg at 1 year after post-operative, the intraocular pressure was stability after the operation. UBM showed that there was a certain gap between ICL and the lens. During the follow-up period,no complications such as cataract,chronic uveal infusion were found. Conclusion Phakic posterior chamber ICL implantation is effective,safe and reliable method for the correction of high myopia.
出处 《中国医师进修杂志》 2010年第18期9-11,共3页 Chinese Journal of Postgraduates of Medicine
关键词 近视 晶状体植入 眼内 Myopia Lens implantation, intraocular
  • 相关文献

参考文献5

  • 1Huang D,Schallhorn SC,Sugar A,et al. Phakic intraocular lensimplantation for the correction of myopla: a report by the American Academy of Ophthalmology. Ophthalmology,2009,116 (11):2244-2258.
  • 2张淑萍,叶子隆,马自勤,杨连静,李晋华.有晶状体眼后房型可植入接触镜矫治高度近视初步报告[J].中国实用眼科杂志,2008,26(11):1259-1260. 被引量:1
  • 3Kim JH,Kim MS,Hahn TW,et al Five years results of photorefractive keratectomy for myopia. J Cataract Refract Surg,1997,23 (5): 731-735.
  • 4Chun YS,Park IK,Lee HI,et al. Iris and trabecular meshwork pigment changes after posterior chamber phakic intraocular lens implantation. J Cataract Refract Surg,2006,32(9): 1452-1 458.
  • 5藏晶,鲍炯琳,黄加兵,王蓓,林文雄.有晶体眼虹膜扣夹型人工晶体植入术矫正超高度近视[J].中国实用眼科杂志,2007,25(3):260-262. 被引量:4

二级参考文献12

  • 1王晓瑛,褚仁远,周行涛,张红霞,周传清,任秋实.晶状体眼前房型人工晶状体植入术矫正高度近视后放大率与视力的关系[J].中华眼科杂志,2005,41(11):990-994. 被引量:16
  • 2J imenez Alfaro I,Benitez del Castillo JM ,Garcia Feijoo J ,et al.Safety of posterior chamber phakic int raocular lenses for t he correction of high myopia:anterior segment changes after pos2 terior chamber p hakic int raocular lens implantation [J].Opht halmology,2001,108( 1 ) : 90.
  • 3ZaldivarR, Rleur G, Oscherow S.The phakic intraoeular lens implant: in-depth focus on posterior chamber phakic IOLs.Curr Opin Ophthalmol, 2000,11 : 22-34.
  • 4Trindade F, Pereira F.Exchange of a posterior chamber phakicint raocular lens in a highly myopic eye [J].J Cataract Refract Surg, 2000,26 (5):773.
  • 5Bloomenstein MR, Dulaney DD, Barnet RW,et al.Posteriorchamber p hakic int raocular lens for moderate myopia and hy2peropia [J].Optometry, 2002,73 (7) : 435.
  • 6Rosen E, Gore C.Staar Collamer posterior chamber phaki int raocular lens to correct myopia and hyperopia [J].J Cataract Refract Surg, 1998,24(5):596.
  • 7Emara B, Probst LE ,Tingey DP, et al.Correlation of inter laser in situ keratomileusis.J Cataract Refract Surg, 1998,24 : 1320-1325.
  • 8Colin J, Robinet A, Cochener B.Retinal detachment after clear lens extraction for high myopia-seven-year follow-up.Ophthahnoiogy, 1999, 106 : 2281-2284.
  • 9Sanders DR,Vukich JA,Doney K,et al.Ophthahnology,2003,110 (2) : 255-266.
  • 10Lackner B, Pieh S, Hanselmayer G, et al.Ophthalmology,2003,110 ( 11 ) :2153-2161.

共引文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部