摘要 马来西亚巴贡水电站的放水孔具有水头高、流速大、空化、空蚀非常突出的问题,以及运行时间长、施工技术难度大等特点和难点。在设计中,通过多方案比选、2次水工模型试验、国内外专家咨询,最终借鉴国外成熟的技术,选用蝶阀、锥阀及椭圆形消能室的方案,合理、可靠、有效地解决了放水孔的水力学、结构等难题。该设计方案最终得到业主、工程师代表和特别咨询团专家的批准和同意。目前放水孔施工完毕,即将投入运行。 The Bakun outlets are characterized by high head, large flow velocity, severe cavitation and erosion, and long operation time, great construction difficulties and technical challenges. In design, the alternative of butterfly valve, cone valve and oval stilling chamber is selected through comparison of many options, two hydraulic model tests and consulting by experts from China and abroad, which solves the problems of hydraulics and structure effectively and reasonably. The design alternative is finally approved by the Employer, the Engineer's Representative and experts of SCP. Currently, the outlets construction is completed and will be put into operation soon.
作者 卞全 刘少斌
出处 《西北水电》 2010年第3期29-33,49,共6页 Northwest Hydropower
关键词 巴贡水电站 放水孔 水力学 水工模型 试验 锥阀 消能室 Bakun hydropower project outlets hydraulics hydraulic model test cone valve stilling chamber
  • 相关文献

参考文献7

  • 1马来西亚巴贡水电站工程CW2标业主.Employer's Requiremerits- Bakun Hydroelectric Project, Package CW2-Main Civil Works, Volume 2 of 7, Books 1 and2 [Z] ,2001.
  • 2严优丽,范建朋,杨建红,等.马来西亚巴贡水电站工程概念设计报告[R].西安:西北勘测设计研究院,2002.
  • 3卞全,陈炀,王康柱.马来西亚巴贡水电站放水孔设计准则[R].西安:西北勘测设计研究院,2004.
  • 4严根华,胡去劣,陈发展.马来西亚巴贡水电站放水孔水工模型试验研究[R].南京:南京水利科学研究院,2005.
  • 5王君利,安盛勋,范建朋,等.放水孔运行条件及有关设计问题[R].西安:西北勘测设计研究院,2005.
  • 6陈炀,罗林,王海峰,等.放水孔设计比较方案报告[R].西安:西北勘测设计研究院,2005.
  • 7张晓莉,刘少斌,卫勇,等.马来西亚巴贡水电站放水孔模型试验研究成果报告[R].西安:西北勘测设计研究院,2007.