UASB反应器预处理高浓度NH4^+-N废水,采用较低的C/N,降低后续处理的NH4^+-N负荷.在反应器内部进行短程硝化与反硝化,经过75d的实验得出,反应器内的最佳控制条件:温度20—30℃,pH值7.0—8.0,C/N3.5~4.5.NH4^+-N浓度在500mg/L左右,去除率达到40%,并且反应器运行稳定,可以作为对高浓度NH4^+-N废水的预处理.
The pretreatment of high concentration NH4^+-N wastewater was carried out by UASB reactor and a lower C/N was used to reduce the NH4^+-N load of the follow-up treatment. By using shortcut nitrification-denitrification in the reactor for 75 d experimental cycles,the best control condition of reactor were obtained as follows :temperature was 20-30 ℃ ;pH was 7.0-8.0;C/N was 3.5-4.5;the concentration of NH4^+-N was about 500 mg/L. The removal rate attained 40%. Running steadily,the reactor could be used as the pretreatment of high concentration NH4 -N wastewater.