摘要 通过实验数据论述了气质联用仪在二氧化硫气体分析中的应用,对采用选择离子监测(Select Ion Mon iringSIM)模式分析二氧化硫的线性、灵敏度和数据重复性进行了考察,探讨了GC-MS对二氧化硫气体定量分析的可靠性,并给出了相应的色谱分析条件及谱图。 The application of gas chromatography-mass spectrometer for analysis of sulfur dioxide gas is discussed by means of experimental data,the linear,sensitivity and repeatability of the experimental data by gas chromatography-mass spectrometer with select ion monitoring mode are investigated,the realiability of quantitive analysis of sulfur dioxide by GC-MS is evaluated,the corresponding analysis conditions and spectra are presented.
出处 《低温与特气》 CAS 2010年第3期34-36,共3页 Low Temperature and Specialty Gases
关键词 GC-MS 离子监测模式 大气污染物 全扫描和选择离子扫描 质量数 线性 测量重复性 GC-MS ion monitoring mode air pollutant full-scan and select ion monitoring mass number 64 linear measurement repeatability