期刊文献+

地表水样品中10种卤代烃测定方法的优化 被引量:8

Optimization for 10 Halohydrocarbons Determination in Surface Water
下载PDF
导出
摘要 对地表水样品中10种卤代烃测定方法进行优化,找出空白偏高的原因。方法优化后的加标回收率为90.1%~104%,相对标准偏差为1.1%~6.9%,检出限为0.000 3μg/L^2.0μg/L,可满足地表水环境质量分析要求。 Determination method for 10 halohydrocarbons in surface water was optimized to combine 4 tests method and to solve higher blank values of some components.The results showed recoveries of 10 halohydrocarbons ranged from 90.1% to 104%,the relative standard deviation between 1.1% to 6.9%,and the detection limit between 0.000 3 μg/L to 2.0 μg/L.The method met the need for 10 halohydrocarbons detection of surface water environmental quality standard.
出处 《环境监测管理与技术》 2010年第3期62-64,共3页 The Administration and Technique of Environmental Monitoring
关键词 卤代烃 顶空进样 地表水 Halohydrocarbons Headspace gas chromatography Surface water
  • 相关文献

参考文献7

二级参考文献6

  • 1何燧源 徐斌文 等.HSGC法测定工业废水中微量氯仿[J].环境杂志,1984,3:25-27.
  • 2中国环境优先监测研究课题组.环境优先污染物[M].中国环境出版社,1989..
  • 3宋仁元(译),水和废水标准检验法(第15版),1985年,1117页
  • 4何燧源,环境杂志,1984年,3卷,25页
  • 5《水和废水监测分析方法指南》编委会.水和废水监测分析方法指南[M]·下册[M].北京:中国环境科学出版社,1997..
  • 6国家环境保护总局《水和废水监测分析方法》编委会.水和废水监测分析方法·第四版[M].北京:中国环境科学出版社,2002.291-298,324-340.