期刊文献+

SJM Regent机械瓣膜应用体会

原文传递
导出
摘要 目的 总结SJMR机械瓣应用经验.方法 对30例主动脉瓣病变患者选择了SJMR机械瓣置换,其中17号瓣9例,19号瓣13例、21号瓣5例,23号瓣3例.结果 本组无手术死亡.术后6个月复查心脏超声表明各主要指标均较术前明显改善.随访期间无死亡,未发现与机械瓣膜相关的并发症.结论 SJMR机械瓣可以使一部分小主动脉瓣环患者避免了主动脉瓣环切开成形,同时最大程度地获得有效瓣口面积,更好地维护了血流动力学的稳定.
作者 许咏冬
出处 《中国医师杂志》 CAS 2010年第6期797-799,共3页 Journal of Chinese Physician
  • 引文网络
  • 相关文献

参考文献5

  • 1刘锋,龚光甫,熊炼,刘立明,张伟.275例主动脉瓣置换术应用连续缝合法的临床观察[J].中国医师杂志,2006,8(4):487-488. 被引量:5
  • 2Casali G,Luzi G,Vicchio M,et al.Echocardiographic follow-up after implanting 17-mm Regent mechanical prostheses.Asian Cardiovasc Thorac Ann,2008,16 (3):208-211.
  • 3Minardi G,Manzara C,Creazzo V,et al.Evaluation of 17-mm St.Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography.J Cardiothorac Surg,2006,19(1):27-33.
  • 4Sezai A,Kasamaki Y,Abe K,et al.Assessment of the St.Jude Medical Regent prosthetic valve by continuous-wave Doppler and.dobutamine stress echocardiography.Ann Thorac Surg,2010,89(1):87-92.
  • 5程力剑,张尔永,郭应强.19mm St.Jude Regent瓣有效瓣口面积和血流动力学的早期在体研究[J].中国胸心血管外科临床杂志,2007,14(4):256-260. 被引量:8

二级参考文献17

  • 1王红兵,周更须,郑奇军,陈文生,蔡振杰,刘维永.小主动脉瓣环患者主动脉瓣置换术41例[J].中国胸心血管外科临床杂志,2006,13(1):52-53. 被引量:8
  • 2罗军,朱晓东,萧明第,刘迎龙,孙立忠,吴信.围术期瓣膜替换术死因及相关因素分析[J].中华胸心血管外科杂志,1996,12(6):330-332. 被引量:37
  • 3llejo JL,Gonzalez-Santos JM,Albertos J,et al.Eight years,Experience with the Medtronic-Hall valve prosthesis.Ann Thorac Surg,1990,50:429.
  • 4Rahimtoola SH.The problem of valve prosthesis-patient mismatch.Circulation,1978,58(1):20-24.
  • 5Milano AD,De Carlo M,Mecozzi G,et al.Clinical outcome in patients with 19-mm and 21-mm St.Jude aortic prostheses:comparison at long-term follow-up.Ann Thorac Surg,2002,73(1):37-43.
  • 6Koch CG,Khandwala F,Estafanous FG,et al.Impact of prosthesis-patient size on functional recovery after aortic valve replacement.Circulation,2005,111(24):3221-3229.
  • 7Pibarot P,Dumesnil JG.Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention.J Am Coll Cardiol,2000,36(4):1131-1141.
  • 8Penta de Peppo A,Zeitani J,Nardi P,et al.Small "functional" size after mechanical aortic valve replacement:no risk in young to middle-age patients.Ann Thorac Surg,2005,79(6):1915-1920.
  • 9Blais C,Dumesnil JG,Baillot R,et al.Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement.Circulation,2003,108(8):983-988.
  • 10Knez I,Rienmuller R,Maier R,et al.Left ventricular archtecture after valve replacement due to critical aortic stenosis:an approach to disqualify the myth of valve prosthesispatient mismatch.Eur J Cardiothorac Surg,2001,19(6):797-805.

共引文献11

;