期刊文献+

自动气象站雷电防护分析与探讨 被引量:24

Lightning protection for automatic weather station
下载PDF
导出
摘要 目前,地面遥测系统正逐步替代传统的人工气象观测,雷电电磁脉冲对地面遥测系统的安全运行构成了很大的威胁。本文详细介绍了自动气象站直击雷、感应雷防护措施、共用接地等防雷技术措施及自动气象站的雷电防护实例,对如何有效防范雷电灾害,做好自动气象站的防雷工作有一定的指导意义。 At present, the traditional artificial meteorological observation is gradually substituted by ground telemetry system, and lightning electromagnetic impulse greatly affects the safe operation of system. This paper introduces some lightning protection measures of automatic weather station in the aspects of protection for direct lightning, induced lightning and common ground system. The examples of lightning protection for atttomatic weather station are also analyzed,which provides a reference for lightning disaster protection and doing a good job on lightning protection of automatic weather station
作者 吴明江 牛萍
出处 《气象水文海洋仪器》 2010年第2期99-102,共4页 Meteorological,Hydrological and Marine Instruments
关键词 自动气象站 防雷 探讨 automatic weather station lightning protection discussion
  • 相关文献

参考文献3

  • 1中国气象局.气象信息系统旨击电磁脉冲防护规范[M].北京:气象出版社,2000.
  • 2中国气象局.气象台(站)防雷技术规范[M].北京:气象出版社,2000.
  • 3GB50057-1994.建筑物防雷设计规范[S].[S].,..

共引文献61

同被引文献74

引证文献24

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部