摘要
介绍某电厂存在运行中轴加风机电机频繁烧损问题的分析与处理过程。结合现场,分析了导致电机烧损的多种原因,指出轴封加热器疏水多级U型水封工作不稳定及风机与电机直接连接方式不合理等因素,确认风机出口管道积水堵塞,造成风机内蒸汽带压外泄致电机进汽水,是电机频繁烧损的主要原因。采取了相关技术措施使问题得以彻底解决。
This paper described the analysis and processing of the motor frequent burning problems in axial fan of a power plant.Analyzed the reasons leading to motor burning and pointed out the insecurity of hydrophobic multi-level seal heater U-seal job,the inconsistency of direct connection with the motor fan and other factors.Confirmed that the main factor leaded frequent burning is fans blocked export pipeline water and fans inside the steam leaking under pressure to call into the soda machine.Technical measures to take related to the problem can be completely resolved the problems and provide reference.
出处
《电力科学与工程》
2010年第6期63-64,67,共3页
Electric Power Science and Engineering
关键词
电机
烧损
积水
管道
畅通
motor
burning
stagnant water
pipeline
smooth