摘要 目的:总结葡萄糖钳夹技术护理中的注意事项。方法:对30例葡萄糖钳夹试验进行观察、评估分析。结果:葡萄糖钳夹试验顺利、受试者安全、静脉管道通畅、血标本合格。结论:葡萄糖钳夹试验前物品、设备、环境的充分准备,建立良好的静脉通路,试验中对受试者的人文关怀是试验的基础,是试验顺利进行、科研数据准确的保证。 Objective: To summary nursing highlights in the hyperinsulinemie euglycemie clamp technique. Methods:A hyperinsulinemic euglyeemie clamp technique was applied into the study of methodology in 30 subjects. Results: The hyperinsulinemic euglycemic clamp test was successfully fufilled. Conclusions: Careful preparation before test,setting up good vein access and humanistic care for subjects are crucial to the qualified samples which will provide accurate data for scientific research.
机构地区 河北省人民医院
出处 《护理实践与研究》 2010年第15期39-41,共3页 Nursing Practice and Research
基金 河北省卫生厅指导性项目 编号:20090221
关键词 葡萄糖钳夹技术 胰岛素抵抗 静脉留置针 护理 Glucose clamp technique Insulin resistance Intravenous catheter Nursing
  • 相关文献

参考文献8

二级参考文献51

  • 1中华医学会糖尿病学分会代谢综合征研究协作组.中华医学会糖尿病学分会关于代谢综合征的建议[J].中国糖尿病杂志,2004,12(3):156-161. 被引量:3058
  • 2陆蔚,贾伟平,包玉倩,项坤三,朱瑞雯.扩展高胰岛素-正葡萄糖钳夹技术的静脉置管方法及护理要点[J].上海医学,2004,27(7):511-512. 被引量:7
  • 3呼庆红,梁真,罗国春,王亚燕,陈楠.67例病人高葡萄糖钳夹试验中护理问题及对策[J].护理学报,2007,14(1):48-49. 被引量:4
  • 4Porte DJ.Banting Lecture 1990.β-cells in type Ⅱ diabetes mellitus.Diabetes,1991,40:166—180.
  • 5Pratley RE,Weyer C.The role of impaired early insulin secretion in the pathogenesis of type Ⅱ diabetes mellitus.Diabetologia,2001,44:929—945.
  • 6McGuire EAH, Helderman J H, Tobin JD, et al. Effects of arterial versus venous sampling on analysis of glucose kinetics in man. J Appl Physiol, 1976, 41:565-573.
  • 7DeFronzo RA, Tobin JD, Andres R. Glucose clamp technique: a method for quantifying insulin secretion and resistance. Am J Physiol, 1979, 237:E214-E223.
  • 8Chiu KC, Cohan P, Lee NP, et al. insulin sensitivity differs among ethnic groups with a compensatory response in β - cell function. Diabetes Care, 2000,23 : 1353-1358.
  • 9Stumvoll M, Gerich J. Clinical features of insulin resistance and beta cell dysfunction and the relationship to type 2 diabetes. Clin Lab Med, 2001, 21: 31-51.
  • 10Dariush E. In praise of the hyperglycemic clamp, a method for assessment of β - cell sensitivity and insulin resistance. Diabetes Care, 1996, 19:278-286.