期刊文献+

4mm管换热器降低制冷剂充注量实验研究 被引量:11

Experimental studies on reducing refrigerant charging quantity in heat exchanger with 4mm diameter tubes
下载PDF
导出
摘要 本文利用最新研发的4mm管换热器分别对分体机进行充注R410A、R290的性能实验。实验结果表明:采用4mm管换热器,在保持性能不变的情况下,不仅可以有效的降低换热器体积和成本,也能明显降低制冷剂充注量。 investigated. cost, but also Based on the new 4mm tube - fin heat exchanger, three air -conditioners using R410A and 11290 were The experimental results showed that 4mm tube - fin heat exchanger not only can reduce its volume and can obviously reduce refrigerant charging quantity.
出处 《制冷技术》 2010年第2期26-27,共2页 Chinese Journal of Refrigeration Technology
基金 广东佛山市顺德区科技计划项目:新型高效空调换热器研发及产业化(编号2008KJ005)
关键词 4mm管 换热器 制冷剂 充注量 4mm diameter tube, heat exchanger, refrigerant, charging quantity
  • 相关文献

参考文献3

  • 1中华人民共和国标准GB/T7725-2004((房间空气调节器》[S].
  • 2Household and similar electrical appliances - Safety - Part 2 - 40 : Particular requirements for electrical heat pumps, air - conditioners and dehumidifiers. IEC 60335 - 2 - 40 [ S ]. 2002:57 - 63.
  • 3Refrigerating systems and heat pumps - Safetyand environmental requirements - Part 1 : Basic requirements, definitions, classification and selection criteria. EN 378 - 1 [S]. 2008:44 -46.