期刊文献+

陶瓷对陶瓷全髋关节置换术的初步体会 被引量:6

Primary ceramic-on-ceramic total hip arthroplasty results:a minimal follow-up of 24 months
原文传递
导出
摘要 目的 回顾分析本组陶瓷对陶瓷全髋关节置换术的临床结果 ,探讨行全陶人工髋关节置换的手术体会.方法 本组在2000年3月~2008年4月间,对行陶瓷对陶瓷全髋关节置换术的患者进行随访,随访时间超过 24个月的有202例(269髋),其中男123例(178髋),女79例(91髋),平均年龄46岁,随访时间平均41(24~122)个月.所有这些患者均进行了临床和影像学评估.结果 本组患者术前 Harris评分平均 53.47 (3~85)分 , 术后平均为90.66 (59~100)分.术后随访无患者有关节异响的主诉,未见假体松动,未发生假体周围感染,无翻修患者.无可观察到的磨损和骨溶解,无明显异位骨化.本组患者术中出现1例边缘崩裂.四种不同公司的髋臼对患术后Harris评分无显著影响.结论 本研究的短期随访结果 显示,现代陶瓷对陶瓷全髋关节置换术对于年轻的骨质量较好的患者是一种良好的选择,但需更长期的随访以验证其长期疗效. Objective To report the clinical results of ceramic-on-ceramic total hip arthroplasty in a minimal follow-up of 24 months. Methods We retrospectively evaluated the clinical and radiological results of primary ceramic-on-ceramic total hip arthroplasty in 202 patients ( 269 hips) performed from March 2000 to April 2008. There were 123 male patients (178 hips) and 79 female patients (91 hips). Their average age was forty-six years. The mean follow-up time was 41 (24 - 122) months. Results The average Harris score improved from 53.47 ( 3 - 85 ) points preoperatively to 90. 66 ( 59 - 100 ) points postoperatively. No patient demonstrated radiological loosening, osteolysis or heterotopic ossification. No prosthesis was revised or infected. Squeaking was not recorded in any hip. One ceramic liner was chipped intraoperatively. There was no significant difference among four types of ceramic cups. Conclusions Based on ourexperience, contemporary ceramic-on-ceramic total hip arthroplasty offers a promising choice for young, active patients. Longer follow-up time is required to demonstrate its long term results.
出处 《中华关节外科杂志(电子版)》 CAS 2010年第3期8-11,共4页 Chinese Journal of Joint Surgery(Electronic Edition)
关键词 关节成形术 置换 陶瓷 外科手术 Arthroplasty, replacement, hip Ceramics Surgical procedures, operative
  • 相关文献

参考文献20

  • 1Charnley J,Cupic Z.The nine and ten year results of the low-friction arthroplasty of the hip.Clin Orthop,1973,95(1):9-25.
  • 2Dumbleton JH,Manley MT,Edidin AA.A literature review of the association between wear rate and osteolysis in total hip arthroplasty.J Arthroplasty,2002,17(5):649-661.
  • 3Tipper JL,Hatton A,Nevelos JE,et al.Alumina-alumina artificial hip joints.Part Ⅱ:characterisation of the wear debris from in vitro hip joint simulations.Biomaterials,2002,23(16):3441-3448.
  • 4Fisher J,Galvin A,Tipper J,et al.Comparison of the functional biological activity and osteolytic potential of ceramic on ceramic and cross linked polyethylene bearings in the Hip.∥D'Antonio,Dietrich M (eds).Bioceramics and alternative bearings in joint arthroplasty.10th Biolox Symposium,2005:21-24.
  • 5Murphy SB,Ecker TM,Tannast M.Two-to 9-year clinical results of alumina ceramic-on-ceramic THA.Clin Orthop Relat Res,2006(453):97-102.
  • 6Yoo JJ,Kim YM,Yoon KS,et al.Alumina-on-alumina total hip arthroplasty.A five-year minimum follow-up study.J Bone Joint Surg Am,2005,87(3):530-535.
  • 7D'Antonio J,Capello W,Manley M,et al.New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty.J Arthroplasty,2002,17(4):390-397.
  • 8Bizot P,Hannouche D,Nizard R,et al.Hybrid alumina total hip arthroplasty using a press-fit metal-backed socket in patients younger than 55 years.A six-to 11-year evaluation.J Bone Joint Surg Br,2004,86(2):190-194.
  • 9George E,Pericles P,Kyriakos A,et al.Primary cementless total hip arthroplasty with an alumina ceramic-on-ceramic bearing results after a minimum of twenty years of follow-up.J Bone Joint Surg Am,2010,92(3):639-644.
  • 10Widmer KH.A simplified method to determine acetabular cup anteversion from plain radiographs.J Arthroplasty,2004,19(3):387-390.

二级参考文献7

  • 1高辉,寇伯龙,吕厚山.全髋置换治疗先天性髋臼发育不良临床疗效观察[J].中国矫形外科杂志,2006,14(23):1778-1780. 被引量:16
  • 2Letitia B,Robert K,Meera S,et al.Early failure due to osteolysis associated with contemporary highly cross-linked ultra-high molecular weight polyethylene.A case report[ J ].J Bone Joint Snrg (Am),2004,86:1051-1056.
  • 3Sedel L.Evolution of alumina-on-alumina implants:a review[ J ].Clin Orthop,2000,379:48-54.
  • 4Heisel C,Silva M,Schmalzried TP.Beating surface options for total hip replacement in young patients[ J ].J Bone Joint Surg (Am),2003,85:1365-1378.
  • 5Garino,JP.Ceramic-on-ceramic total hip arthroplasty:the USA experience.Bioceramics and alternative bearings in joint arthroplasty[ C ].Springer,Darmstadt,2005,95-100.
  • 6Widmer KH.Is there really a “safe zone” for the placement of total hip components? Bioceramics and altemative bearing in joint arthroplasty[ C ].Springer:Darmstadt,2006,249-252.
  • 7Garino JP.Modem ceramic-on-ceramic total hip systems in the United States early results[ J ].Clin Orthop,2000,379:41 -47.

共引文献9

同被引文献82

引证文献6

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部