摘要 为研究截面尺寸对玻璃纤维加固砖柱轴压性能的影响,进行了39个(13组)不同截面尺寸的砖砌体柱经玻璃纤维增强材料全长包裹加固后的轴心受压试验,分析了试件截面尺寸、砂浆强度以及黏贴层数等因素对加固后试件极限强度的影响。试验结果表明:这种加固方式能不同程度提高砖柱的极限承载力,极限强度随加固层数线性变化。参照FRP加固混凝土柱的基本原理,建立了FRP加固砖柱的有效约束区与非有效约束区。 To investigate the effect of sectional size on axial compression performance of brick masonry columns wrapped by glass fiber reinforced plastic,34(13 groups) brick masonry columns wholy wrapped by glass fiber reinforced plastic(GFRP) sheets were tested under axial compression.The influences of specimen sectional size,mortar strength and stick layers of GFRP sheetsets on the ultimate strength of reinforced brick masonry columns were analysed.The experimental results indicate that GFRP sheets can obviously enhance the ultimate axial compression strength of brick columns with the ultimate strength of the reinforced testing column increasing linearly with stick layers.Based on the principle of FRP reinforced concrete square columns,a calculation method of effective controlling area of brick masonry square columns reinforced with GFRP was presented.
出处 《福建工程学院学报》 CAS 2010年第3期214-217,共4页 Journal of Fujian University of Technology
基金 福建省科技厅青年人才项目(2007F3007)
关键词 砖砌体柱 玻璃纤维 包裹加固 截面尺寸 brick masonry column glass fiber reinforced plastics(GFRP) wrapped strengthening sectional size
  • 相关文献

参考文献5

二级参考文献15

  • 1GB50011—2001.建筑抗震设计规范.[S].,..
  • 2GB50003—2001 124.砌体结构设计规范.[S].,..
  • 3Mirmiran Amir, and Shahawy Mohsen. "Behavior of Concrete Columns Confined by Fiber Composites" [J], ASCE Journal of Structural Engineering, 1997, 123 (5): 583 ~ 589
  • 4Toutanji Houssam A., "Stress - Strain Characteristics of Concrete Columns Externally Confined with Advanced Fiber Composite Sheets" [J], ACI Material Journal, 1999, 96 (3) 397~404
  • 5Shahawy M., Mirmiran A., and Beitelman T., "Tests and Modeling of Carbon- wrapped Concrete Columns" [J], Composites: Part B: engineering, 2000, 31, 471 ~ 480
  • 6Matthys S., Taerwe L., and Audenaert K., "Test on Axially Loaded Concrete Columns Confined by Fiber Reinforced Polymer Sheet Wrapping" [A], In: Dolan CW, Rizkalla S., and Nanni A., editors. Proceedings of the 4th Internatonal Symposium on Fiber Reinforced Polymer Reinforcement for Reinforced Concrete Structures, SP- 188 [C], American Concrete Institute, 1999, 243 ~ 253
  • 7Saafi Mohamed, Toutanji Houssam A., and Li Zongjin, "Behavior of Concrete Columns Confined with Fiber Reinforced Polymer Tubes" [J], ACI Material Journal, 96 (4), 1999,500 ~ 509
  • 8Richart F. E., Brandtzaeg A., and Brown R. L., "A Study of the Failure of Concrete under Combined Compressive Stressed" [R], Engrg. Experimental Station bull., No. 185,University of Illinois, Urbana, Ill., 1928
  • 9Lam L. And Teng J. G., "Compressive strength of FRPconfined concrete in rectangular columns" [J], FRP Composites in Civil Engineering, Published by Elsevier Science Ltd.Vol. 1, Hong Kong, 2001,: 335 ~ 343
  • 10Sheikn S. A., and Uzumeri S. M., "Strength and Ductility of Tied Concrete Columns" [J] Journal of Structural Division,ASCE, 1980, 106 (5): 1079~1102

共引文献140

同被引文献16

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部