摘要
大型火力发电机组的设备选型一般将动叶可调轴流风机选择为锅炉送风机,动叶可调轴流风机在运行中具有操作方便、调节性能好等优点,但其核心机构均为动调执行机构,其结构精密,对装调、维护均有较高要求,本文试图分析改型风机在实际运用中的常见异常并提出处理建议。
It is common to choose the furnace blower as the movable blade variable shaft blower in the large scale thermal power sets. The movable blade variable shaft blower has many advantages, such as convenient operation and fine justment and maintenance is management characteristic, higher as the core device which have a accurate fabric. The paper tries to analyze though the requirement in the installation, ad- are all movable adjustment execution machine the common abnormity of the remodel blower in the practical application and present the disposition proposal
出处
《贵州电力技术》
2010年第4期16-18,共3页
Guizhou Electric Power Technology
关键词
送风机
动叶
异常分析
故障处理
blower
movable blade
abnormity analysis
malfunction disposition