时域反射技术测量海洋沉积物含水量的研究 被引量:20

Research of Time Domain Reflectometry in Measuring Water Content of Marine Sediments
下载PDF
导出
摘要 时域反射技术(TDR)已被广泛应用于农业、地学等领域的水体分布特征研究。经实验发现,当沉积物孔隙水的盐度高于约0.5%时,利用传统的TDR探针无法测量沉积物的含水量。通过对TDR探针进行改进,发现加套管的TDR探针可以测量高盐分沉积物的含水量。观测了向干砂中加入盐度为0、0.5%、2%和3.5%溶液过程中介电常数的变化情况,初步建立了此种情况下沉积物的介电常数与含水量间的经验关系式。这一研究将为TDR在海洋沉积物含水量和水合物饱和度测量等方面的应用提供新的方法与思路。 Time Domain Reflectometry(TDR) has been widely used in water system investigation in agriculture,geosciences,etc.The experiments in this paper show that with a conventional TDR probe we can not measure water content of the sediment where pore water salinity is higher than about 0.5% in weight.Therefore,a coated TDR probe was developed and successfully used in measuring water content of the high-salinity sediments.The dielectric constants were observed when adding solutions with 0,0.5,2 and 3.5 percent of salinity to the dry sands respectively,and the results were used to reveal the empirical relations between water content and dielectric constants,which enabled us measuring water content of marine sediments with TDR.The study have significances for introducing TDR technology in measuring water content and hydrate saturation of marine sediments.
出处 《现代地质》 CAS CSCD 北大核心 2010年第3期622-626,共5页 Geoscience
基金 国家自然科学基金项目(40576028) 国家"海域天然气水合物资源调查与评价"专项项目(GZH200200202) 国土资源部海洋油气资源与环境地质重点实验室基金项目(MRE200921)
关键词 时域反射技术 含水量 高盐度 海洋沉积物 套管探针 Time Domain Reflectometry water content high salinity marine sediment coated probe
  • 相关文献

参考文献19

  • 1Gardner W,Kirkham D.Determination of soil moisture by neutron scattering[J].Soil Science,1952,73(5):391-402.
  • 2Reginato R J,Van Bavel C H M.Soil water measurement with gamma attenuation[J].Soil Science Society of America Journal,1964,28(1):721-724.
  • 3Huisman J A,Hubbard S S,Redman J D,et al.Measuring soil water content with ground penetrating radar:a review[J].Vadose Zone Journal,2003,2(1):476-491.
  • 4Topp G C,Davis J L,Annan A P.Electromagnetic determination of soil-water content:Measurement in coaxial transmission line[J].Water Resource Researh,1980,16(3):574-582.
  • 5Noborio K.Measurement of soil water content and electrical conductivity by time domain reflectometry:a review[J].Computers and Electronics in Agriculture,2001,31(3):213-237.
  • 6Dasberg S,Dalton F N.Time domain reflectometry:field measurement of soil water content and electrical conductivity[J].Soil Science Society of America Journal,1985,49(1):293-297.
  • 7Dalton F N,Herkelrath W N,Rawlins D S,et al.Time-domain reflectometry:Simultaneous measurement of soil water content and electrical conductivity with a single probe[J].Science,1984,224(4652):989-990.
  • 8Regalado C M.Time domain reflectometry models as a tool to understand the dielectric response of volcanic soils[J].Geoderma,2003,117(3/4):313-330.
  • 9Wright J F,Nixon F M,Dallimore S R,et al.A method for direct measurement of gas hydrate amounts based on the bulk dielectric properties of laboratory test media[M] //Mori Y H.The Proceedings of the Fourth International Conference on Gas Hydrate.Yokohama:Keio University,2002:745-749.
  • 10Hu G W,Ye Y G,Zhang J,et al.Acoustic properties of gas hydrate-bearing consolidated sediments and experimental testing of elastic velocity models[J/OL].Journal of Geophysical Research,2010,115:B02102,doi:10.1029/2008JB006160.

二级参考文献141

共引文献61

同被引文献268

引证文献20

二级引证文献119

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部