后房型人工晶体倾斜和偏心的活体测量及研究 被引量:17

Measurement and research of posterior chamber intraocular lens tilt and decentration in vivo
原文传递
导出
摘要 目的观察后房型人工晶体在活体眼内的位置情况,倾斜、偏心对术后视力的影响。方法采用通过第3、第4浦肯野影像测量人工晶体倾斜及眼前节照片测量人工晶体偏心的方法,对64只白内障囊外摘除及人工晶体植入术后的活体眼进行测量。结果平均倾斜(6.95±2.46)°;平均偏心(0.66±0.28)mm。对称性固定袋袋组与不对称性固定袋沟组比较,倾斜和偏心差异均有非常显著性(P<0.001)。其中袋袋固定方式中,无放射状撕裂平均偏心最低0.32mm。倾斜>9.65°同时偏心>1.02mm时,眩光、单眼复视等症状明显。结论人工晶体于无前囊放射状撕裂的囊袋中最稳定,保持中心位置最持久。倾斜、偏心不同程度地影响术后视力质量。 Objective To observe the situation of implanted lenses in vivid eyes and postoperative visual acuity affected by the lens tilt and decentration. Methods 64 eyes underwent extracapsular cataract extraction with posterior chamber lens implantation. Postoperatively, the lens tilt was measured by means of the 3 rd and 4 th Purkinje images, and the decentration of lenses was measured on the anterior segment photographs taken with a fundus camera. Results The mean tilt was (6.95±2.46)°, and the mean decentration, (0.66±0.28) mm. There were a significant differences in the tilt and decentration between the symmetrical bag/bag and asymmetrical bag/sulcus group ( P <0.001). Bag/bag group without tear had less average decentration 0.32 mm. When tilt was more than 9.65 degrees and decentration was more than 1.02 mm, the symptom such as glare or monocular diplopia was obvious. Conclusions These results indicate that in the bag without tear, the lenses have a perfect stability and consistent centration, and the tilt and decentration of the implanted lens affect postoperative visual quality in varying degrees.
作者 陆斌 沈泽民
出处 《中华眼科杂志》 CAS CSCD 北大核心 1999年第1期40-42,共3页 Chinese Journal of Ophthalmology
关键词 浦肯野影像 白内障 人工晶体植入术 倾斜 偏心 Lenses, intraocular Purkinje image
  • 相关文献

同被引文献155

引证文献17

二级引证文献75

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部