期刊文献+

检测电压暂降特征量的有效值算法 被引量:13

Detection Method of Voltage Sags Characterizations Using RMS Algorithm
下载PDF
导出
摘要 在简述电压暂降的基本概念、特征量和起因的基础上,介绍了采用有效值算法获取电压暂降特征量的方法,提供了完整的软件处理流程。通过Matlab仿真,验证了全周期有效值算法和半周期有效值算法的有效性,得出了电压暂降起始时刻和终止时刻的延时误差变化曲线。在对起止时刻精度有较高要求的场合,可以利用该曲线进行误差修正,进而得到更为准确的电压暂降持续时间。 According to the basic concepts,characteristics and causes of voltage sags,a root-mean-square(RMS) algorithm method to obtain the characteristics of voltage sags was introduced and a complete software process flow was provided.Through the Matlab simulation,the full-cycle RMS algorithm and the half-cycle RMS al-gorithm were proved and the delay error curve of the start time and end time of voltage sags was obtained.On the occasion for higher precision demand of start-stop time measurement,a more accurate voltage sags duration could be obtained after the error correction by the curve.
出处 《低压电器》 北大核心 2010年第10期48-51,共4页 Low Voltage Apparatus
关键词 电压暂降 检测方法 有效值算法 voltage sags detection method root-mean-square(RMS) algorithm
  • 相关文献

参考文献4

二级参考文献14

  • 1Bollen M H J. Understanding power quality problems, voltage sages and interruptions [M] .New York, IEEE PRESS,2000
  • 2IEC 61000-2-2 EMC Environment: Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems. (1990 ,International standard)
  • 3EN50160 voltage characteristics of electricity supplied by public distribution systems[S]. 1995
  • 4Measurement guide for voltage characteristics[S] . UNIPEDE July 1995
  • 5LarryRay(美).电压骤降和电源间断事故的防范 [J].电气施工与管理,1999,(6):26-27.
  • 6Bollen M H J.Understanding power quality problems,voltage sags and interruptions[J].IEEE PRESS,Piscataway,New Jersey,2000.
  • 7Tunaboylu N S, Collins J E R, Chaney P R.Voltage distur-bance evaluation using the missing voltage technique[J].Proceedings of the IEEE ICHQP VIII,Athens, Greece, 1998.577-582.
  • 8Middlekauff S W, Collins J E R. System and customer imp-act:considerations for series custom power devices[J].IEEE Trans.on Power Delivery,1998,13(1):278-282.
  • 9XIAO Xiang-ning,XU Yong-hai,LIU Liang-guang. Simulation and analysis of voltage sag mitigation using active series voltage injection[A].Proceedings of the 2000 International Conference on Power System Technology (POWERCON2000)[C].Perth,Australia,2000.1317-1322.
  • 10陈警众.电能质量讲座 第二讲 20世纪末对电能质量要求的新发展[J].供用电,2000,17(4):52-54. 被引量:10