期刊文献+

Comparison of the ability of wavelet index and bispectral index for reflecting regain of consciousness in patients undergone surgery 被引量:12

Comparison of the ability of wavelet index and bispectral index for reflecting regain of consciousness in patients undergone surgery
原文传递
导出
摘要 Background Wavelet index (WLI) is a new parameter for monitoring depth of anesthesia based on Wavelet analysis. We observed the change of WLI and bispectral index (BIS) in patients regain of consciousness (ROC) in the absence of frontalis electromyographic (EMG) interference. The aim of this study was to compare the ability of WLI and BIS for reflecting ROC in patients undergone surgery. Methods Twelve patients who were scheduled for maxillofacial surgeries were enrolled in the study. BIS and WLI values were monitored continually. After being given midazolam and remifentanil, patients were asked to squeeze the investigator's hand ever 30 seconds. Patients were continuously given propofol until loss of consciousness (LOC1). Tunstalrs isolated forearm technique was used to test the surgical consciousness in patients. After total muscle relaxation endotracheal intubations were performed, and the patients were connected to a ventilator. Then, propofol was withdrawn until the patients showed regain of consciousness (ROC1) and an awareness reaction. After the command test, patients were readministered with propofol until loss of consciousness (LOC2). After surgery, all of the sedatives were withdrawn, and the patients were let to regain consciousness (ROC2), Results The BIS values of twelve patients at ROC1 after using muscle relaxant were much lower than those at LOC1 and ROC2 without using muscle relaxant, showing statistical significance (P 〈0.05). Meanwhile, the WLI values of twelve patients at ROC1 after using muscle relaxant were much higher than those at LOC1 and equal to ROC2 without using muscle relaxant, showing statistical significances (P 〈0.05) between ROC1 and LOCI. Conclusions This study showed that under muscle relaxation or facial paralysis, when there is no EMG signal, BIS can not accurately reflect regain of consciousness in surgical patients, but WLI can reflect it accurately. So WLI may have advantages for reflecting state of consciousness in surgical patients. Background Wavelet index (WLI) is a new parameter for monitoring depth of anesthesia based on Wavelet analysis. We observed the change of WLI and bispectral index (BIS) in patients regain of consciousness (ROC) in the absence of frontalis electromyographic (EMG) interference. The aim of this study was to compare the ability of WLI and BIS for reflecting ROC in patients undergone surgery. Methods Twelve patients who were scheduled for maxillofacial surgeries were enrolled in the study. BIS and WLI values were monitored continually. After being given midazolam and remifentanil, patients were asked to squeeze the investigator's hand ever 30 seconds. Patients were continuously given propofol until loss of consciousness (LOC1). Tunstalrs isolated forearm technique was used to test the surgical consciousness in patients. After total muscle relaxation endotracheal intubations were performed, and the patients were connected to a ventilator. Then, propofol was withdrawn until the patients showed regain of consciousness (ROC1) and an awareness reaction. After the command test, patients were readministered with propofol until loss of consciousness (LOC2). After surgery, all of the sedatives were withdrawn, and the patients were let to regain consciousness (ROC2), Results The BIS values of twelve patients at ROC1 after using muscle relaxant were much lower than those at LOC1 and ROC2 without using muscle relaxant, showing statistical significance (P 〈0.05). Meanwhile, the WLI values of twelve patients at ROC1 after using muscle relaxant were much higher than those at LOC1 and equal to ROC2 without using muscle relaxant, showing statistical significances (P 〈0.05) between ROC1 and LOCI. Conclusions This study showed that under muscle relaxation or facial paralysis, when there is no EMG signal, BIS can not accurately reflect regain of consciousness in surgical patients, but WLI can reflect it accurately. So WLI may have advantages for reflecting state of consciousness in surgical patients.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2010年第12期1520-1523,共4页 中华医学杂志(英文版)
关键词 frontalis electromyographic activity wavelet index bispectral index tunstall's isolated forearmexperiments regain of consciousness frontalis electromyographic activity wavelet index bispectral index tunstall's isolated forearmexperiments regain of consciousness
  • 相关文献

二级参考文献1

共引文献27

同被引文献47

引证文献12

二级引证文献137

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部