摘要
考察了文献报道的地质样品中Cd同位素测试前的化学分离纯化和富集方法(预处理方法)中的离子交换树脂单柱法回收率低的原因,并在该方法的基础上做了改进,优化了离子交换柱的洗涤顺序和洗液用量。改进后的离子交换树脂单柱法Cd回收率达99.82%,主要干扰元素(Sn、In、Zn、Pb)和基质元素的去除效果均较理想,能更好地满足Cd同位素的测定要求。
The causes of low-recovery for cadmium(Cd) separated and purified by the ion exchange resin one-column procedures were investigated.Based on the ion exchange resin one-column procedures,a proved method was proposed and the washing procedure and the volume of washing solution was adjusted.The results indicated that the recovery of Cd was up to 99.82%,the potential interferences on Cd isotopes(including Sn,In,Zn,Pb and other interfering matrix elements) were present at negligible levels.The improved method could meet the needs of the measurement of Cd isotopic ratio.
出处
《分析测试学报》
CAS
CSCD
北大核心
2010年第6期633-637,共5页
Journal of Instrumental Analysis
基金
国家"973"资助项目(2007CB411402)
国家自然科学基金资助项目(40773034
40873014
40930425)
关键词
Cd同位素
离子交换
分离提纯
预处理
Cd isotope
ion exchange
separation and purification