摘要
对软土地基建筑物的排污排水管道安装方式进行了研究,介绍了施工沉降缝的设置原理,通过对建筑物管道排出室外的第1个检查井在井壁开槽及在井外壁加设挡土板等深化设计,以解决建筑物室内外大沉降差导致排污排水管道变形破裂的实用新型技术。
It's studied for the installation way of pollution discharge and drainage channel of the building on the soft ground,introduced setting principle by the construction subsidence seam. It is a new technology that solve the pollution discharge and drainage channel break caused by the large differential settlement betwween indoor and outdoor of the building,tlirough detailing design for slotting and extra soil shield on the outerwall of the well that the first inspection well of the building pipeline discharge outdoor.
出处
《广东土木与建筑》
2010年第4期41-43,共3页
Guangdong Architecture Civil Engineering
关键词
软土地基
排污排水管道
检查井
沉降
开槽
挡土板
soft ground
pollution discharge and drainage channel
inspection well
subsidence
slot
soil shield