摘要 In China, the technical information currently available both domestically and abroad has been reviewed in an attempt to integrate the technique of ultraviolet air disinfection with Grade Ⅱ filters and develop a sterile conservation-oriented environment. As detection showed, such a sanitary system of air disinfection, integrated by ultraviolet air disinfection and Grade Ⅱ filters can reach the same standard of cleanliness as a high efficiency particle filter. This system easily satisfies the cleaning of air in hospital wards, surpassing the sterile air standards and the requirements of the National Bacteria Indicator (NBI). As a result of this system's efficiency, resources and running costs can be reduced dramatically. Therefore, revision of the national standards of Structural Technical Specification of the Cleaning Operation Department needs to move forward.
作者 Xu Huoju
出处 《China Standardization》 2010年第4期19-25,共7页 中国标准化(英文版)
关键词 conservation-oriented sterile environment standards 空气消毒 国家标准 无菌环境 医院病房 微粒过滤器 化工 消毒卫生制度 技术信息
  • 相关文献

参考文献11

  • 1Codes for Structural Design of Cleaning Operation Department GB 50333-2002 promulgated by Ministry of Health of the People's Republic of China 2002-11.
  • 2Hygienic Standards for Disinfection in hospitals GB 15982-1995 promulgated by Ministry of Health of the People's Republic of China 1995.
  • 3Technical Standards For Disinfection promulgated by Ministry of Health of the People's Republic of China 2002-11.
  • 4Christian Brandt, Uwe Hott, Dorit Sohr, et al. Operating room ventilation with laminar airflow shows no protective effect on the surgical site infection rate in Orthopedic and Abdominal Surgery [J]. Annals of Surgery by American Surgical Association/European Surgical Association U.S., 2008, 248 (5):695-700.
  • 5Salvati E A, Robinson R P. Zeno S M, Koslin B L, Brause B D, Wilson P D. Infection rates after 3175 total hip and total knee replacements performed with and without a horizontal unidirectional filtered air-flow system [J]. J Bone Joint Surg (Am) 1982; 64 (4):5 25-35.
  • 6Cacciari P, Giannoni R, Marcelli E, et al. Cost evaluation of a ventilation system for operating theatre: an ultraclean design versus a conventional one [J]. Ann Ig. 2004;16: 803- 809.
  • 7The American National Standard (ANS). the American Society of Heating, Refrigerating and AirConditioning Engineers,Ventilation of Health Care Facilities ANSI/ASHRAE/ASHE Standard 170-2008[S].
  • 8DIN 1946-4 Ventilation and air conditioning -Part 4: VAC systems in buildings and rooms used in the health care sector [S] DIN Deutsches Institut Berlin, Germany, 11. 2008.
  • 9National Homeland Security Research Center. Biological inactivation efficiency by HVAC in-duct Ultraviolet Light Systems [R]. Test report by United States Environment Protection Agency, 2006.
  • 10Inactivation of virus particles (bacteriophage MS) by Virobuster "Steritube" [R]. Test report by biotec GmbH, Gu tersloh Germany, 2006.