期刊文献+

“三明治”法制备牛血红蛋白分子印迹膜 被引量:2

"Sandwich-Prepare" of a Bovine Hemoglobin Molecularly Imprinted Polymer Membrane
原文传递
导出
摘要 以牛血红蛋白为模板蛋白、丙烯酰胺为功能单体、N,N′-亚甲基双丙烯酰胺为交联单体、过硫酸铵为引发剂,采用"三明治"法制备了牛血红蛋白分子印迹膜.确定了最佳的实验条件,功能单体与交联剂的摩尔配比为40∶1,洗脱剂为1%SDS-10%HAc,其对模板蛋白的洗脱率为47%.结果表明,所制备的蛋白质印迹膜在3.5 h和2.9μmol/L重结合蛋白浓度时,对模板蛋白的吸附量达到最大.该分子印迹膜对模板蛋白的吸附量(0.22 nmol/cm2)明显高于非印迹膜对模板蛋白的吸附量(0.10 nmol/cm2),对血红蛋白、肌红蛋白、溶菌酶和牛血清白蛋白的印迹因子值分别为2.5,1.7,1.3和1.2,说明它对模板蛋白具有一定选择性. A hemoglobin molecularly imprinted polymer membrane(MIPM)was prepared on a glass chip by using water soluble acrylamide as a functional monomer and N,N′-methylenebisacrylamide as a crosslinker.The optimal ratio of functional monomer to crosslinker monomer to form a good membrane is 40∶1.1%SDS-10%HAc was the most effective washing solution which can remove 47% of the template.The absorption reached a maximal value at 3.5 h and at 2.9 μmol/L rebinding concentration.The MIPM showed higher absorb-capacity(0.22 nmol/cm2) to the template protein than that(0.10 nmol/cm2) of the non-imprinted polymer membrane(NIPM).The selectivity experiment carried out in different protein solutions showed that MIPM absorbed more template protein than those that had not been imprinted.The imprinting factor for hemoglobin,myoglobin,lysozyme and BSA were 2.5,1.7,1.3 and 1.2 respectively.
出处 《武汉大学学报(理学版)》 CAS CSCD 北大核心 2010年第3期289-292,共4页 Journal of Wuhan University:Natural Science Edition
基金 国家自然科学基金资助项目(20875024) 湖北省教育厅重大研究项目(Z20081402)
关键词 分子印迹 血红蛋白 丙烯酰胺 分子识别 molecularly imprinting hemoglobin acrylamide molecular recognition
  • 相关文献

参考文献10

  • 1Alexander C, Andersson H S, Andersson L I, et al. Molecular imprinting science and technology; A survey of the literature for the years up to and including 2003[J]. J Mol Recognit, 2006,19 : 106-180.
  • 2Bossi A, Bonini F, Turner A P F, et al. Molecularly imprinted polymers for the recognition of proteins:The state of the art [J].Biosens Bioelectron, 2007,22: 1131-1137.
  • 3McCluskey A, Holdsworth C I, Bowyer M C, et al. Molecularly imprinted polymers (MIPs) :Sensing, an explosive new opportunity [J].Org Biol Chem, 2007, 5:3233-3244.
  • 4Shi H,Tsai W B, Garrison M D, et al. Template-imprinted nanostructured surfaces for protein recognition [J].Nature,1999,398:593-597.
  • 5Zhang Z, Long Y, Nie L,et al. Molecularly imprinted thin film self-assembled on piezoelectric quart crystal surface by the sol-gel process for protein recognition[J]. Biosens Bioelectron ,2006,21 : 1244-1251.
  • 6Tai D F,Lin C Y,Wu T Z,et al. Recognition of dengue virus protein using epitope-mediated molecularly imprinted film[J].Anal Chem, 2005,77: 5140-5143.
  • 7Tai D F,Lin C Y,Wu T Z,et al. Artificial receptor in serologic tests for the early diagnosis of dengue virus infection[J].Clin Chem, 2006,52 : 1486-1491.
  • 8Hsu C Y,Lin H Y,Chou T C,et al. Incorporation of styrene enhances recognition of ribonuclease A by molecularly imprinted polymers[J].Biosens Bioelectron, 2006,22:355-363.
  • 9Lin H Y,Hsu C Y,Chou TC,etal. Themicrocontaet imprinting of proteins.. The effect of cross-linking monomers for lysozyme, ribonuclease A and myoglobin [J]. Biosens Bioelectron, 2006,22 : 534-543.
  • 10Lin H Y,Rick J,Chou T C,et al. Optimizing the formulation of a myoglobin molecularly imprinted thinfilm polymer-formed using a micro-contact imprinting method[J]. Biosens Bioelectron, 2007,22 : 3293-3301.

同被引文献68

  • 1马豫峰,蔡继业.壳聚糖与牛血清白蛋白分子印迹聚合物的制备与表征[J].高分子材料科学与工程,2007,23(2):235-237. 被引量:9
  • 2Alexander C, Andersson H S, Andersson L I, Ansell R J, Kirsch N, Nicholls I A, O' Mahony J, Whitcombe M J. J. Mol. Recognit. [J],2006,19(2) :106.
  • 3Chen L,Xu S,Lia J. Chem. Soc. Rev. [J] ,2011,40:2922.
  • 4Byrne M E,Park K,Peppas N A. Adv. Drug Deliver. Rev. [J] ,2002,54:149.
  • 5Zhang H Q,Ye L,Mosbach K. J. Mol. Recognit. [J] ,2006,19:248.
  • 6Whitcombe M J, Chianella I, Larcombe L, Piletsky S A, Noble J, Porter R, Horgan A. Chem. Soc. Rev. [J], 2011,40 : 1547.
  • 7Turner N W, Jeans C W, Brain K R, Allender C J, Hlady V, Britt D W. Biotechnol. Prog. [J], 2006,22 : 1474.
  • 8Janiak D S, Kofinas P. Anal. Bioanal. Chem. [J], 2007,389 : 399.
  • 9Hansen D E. Biomaterials[J], 2007,28: 4178.
  • 10Bossi A,Bonini F,Turner A P F,Piletsky S A. Biosens. Bioelectron. [J],2007,22:1131.

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部