摘要 为解决凝结水泵通过凝汽器调节门开度来控制凝汽器水位而造成的节流损失问题,上海外高桥第二发电厂将凝结水泵改造为"一用一备"控制方式的变频运行。介绍了凝结水泵改造为变频调速后的运行方式,分析了变频运行中对凝汽器水位的自动控制、2台凝结水泵的连锁保护等问题的控制逻辑策略,并通过对凝结水泵变频运行前后的系统性能比较计算证明了GW级机组凝结水泵采用变频运行对降低能耗,延长设备使用寿命,减小维护量,改善机组运行经济性起到了良好的效果。 In order to resolve the throttling loss problem resulting from the condensate pump controlling the water level of condenser with governing valve, the condensate pumps were retrofitted to frequency conversion operation with the control method of one operation and one standby in Shanghai Waigaoqiao No. 2 Power Plant. Tile operation mode of the condensate pumps has been described after frequency conversion. The problems of the control logic, such as the water level of condenser automation and the chain protection between two condensate pumps, have been analyzed. The performance was compared before and after retrofit; the result showed that the condensate pumps operated in the frequency conversion speed regulation mode can effectively reduce power consumption, extend the equipment service life, reduce equipment maintenance frequency and improve units operating economical efficiency.
作者 俞震华
出处 《中国电力》 CSCD 北大核心 2010年第7期53-56,共4页 Electric Power
关键词 GW级机组 凝结水泵 变频调速 性能分析 1 000 MW units condensate pump frequency control performance analysis
  • 相关文献

参考文献5

  • 1汽轮机设备及其系统[R].上海外高桥第二发电有限责任公司,2005.
  • 2DL5000-2000.火力发电厂设计技术规程[S].[S].,..
  • 3西北电力设计院.电力工程电气设计手册(电气二次部分)[M].北京:中国电力出版社,2006.
  • 4Northwest Electric Power Design Institute.Electrical design guide for electrical power engineering(electric secondary system)[M].Beijing:China Electric Power Press,1991.
  • 5GB 15710-2006电气装置安装工程旋转电机施工及验收规范[S].

共引文献126

同被引文献61

引证文献18

二级引证文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部