期刊文献+

多焦点人工晶状体的发展和临床应用 被引量:9

原文传递
导出
摘要 多焦点人工晶状体是新一代人工晶状体。该晶状体利用其光学特性使通过的光线形成多个焦点,植入后可使白内障患者拥有良好的远、中、近视力,摆脱眼镜的困扰。现就多焦点人工晶状体的设计原理,分类、各型代表品牌及特点、晶状体材料、临床应用时病人的选择、人工晶状体度数的计算、手术方法和要点以及术后视觉质量做一综述。
出处 《中国实用眼科杂志》 CSCD 北大核心 2010年第7期694-698,共5页 Chinese Journal of Practical Ophthalmology
  • 相关文献

参考文献32

  • 1Keates RH,Pearce JL,Schneider RT.Clinical resuts of the multifocal lens[J].J Cataract Refract Surg,1987,13(5):557-560.
  • 2Ravalico G,Baccara F,Rinaldi G.Contrast sensitivity in multifocal intraocular lenses[J].J Cataract Refract Surg,1993,19(1):22-25.
  • 3Wallace RB 3rd.Rofractive cataract surgery and multifocal IOLs[M].Canada:SLACK,2001:179-186.
  • 4Solomon R,Donnenfeld ED.Refractive Intraoeular lenses.Multifocal and Phakic IOLs[J].lnt Ophthalmol Clin,2006,46 (3):123-143.
  • 5Chiam PJ,Chan JH,Haider SI,et al.Functional vision with bilateral ReZoom and ReSTOR intraoculur lenses 6 months after cataract surgery[J].J Cataract Refract Surg,2007,33 (12):2057-2061.
  • 6Steinert RF,Aker BL,Trentacost DJ,et al.A prospective comparative study of the AMO ARRAY zonal-progressive multifacal silicone intraocular lens and a monofocal intraocular lens[J].Ophthalmology,1999,106(7):1243-1255.
  • 7Montes-Mico R,Alio JL.Distance and near contrast sensitivity function after multifocal intraoculac lens implantation[J].J Cataract Refract Surg,2003,29(4):703-711.
  • 8Pieh S,weghaupt H,Skorpik C.Contrast sensitivity and glare disability with diffractive and refractive multifocal intraocular lenses[J].J Cataract Refract Surg,1998,24(5):659-662.
  • 9Hayashi K,Manabe S,Hayashi H.Visnal acuity from far to near and contrast sensitivity in eyes with a diffractive muhifocal intraocular lens with a low addition power[J].J Cataract Refract Surg,2009,35(12):2070-2076.
  • 10Abela-Formanek C,Amon M,Schauersberger J,et al.Results of hydrophilic acrylic,hydrophobic acrylic,and silicone intraocular lenses in uveitic eyes with cataract:Comparison to a control group[J].J Cataract Refract Surg,2002,28(7):1141-1152.

二级参考文献21

  • 1Packer M, Fine IH, Hoffrnan RS. Refractive lens exchange with the array multifocal intraocular lens [J]. J Cataract Refract Surg, 2002,28(3):421 -424.
  • 2Trindade F, Pereira F. Exchange of a posterior chamber phakic intraocu]ar lens in a highly myopic eye[J]. J Cataract Refract Surg, 2000,26(5):773-776.
  • 3Carlson AN,Stewart WC ,Tso PC. Intraocular lens complications requiring removal or exchange[J]. Surv Ophthalmol, 1998,42(5): 417-440.
  • 4Apple DJ. Influence of intraocular lens material and design on postoperative intracapsular cellular reactivity [J]. Trans Am Ophthalmol Soc, 2000,98:257-283.
  • 5Fink AM, Gore C, Rosen ES. Refractive lensectomy for hyperopia[J]. Ophthalmology, 2000,107(8):1540-1548.
  • 6Kohnen T,Koch MJ. Refractive aspects of cataract surgery[J]. Curt Opin Ophthalmol, 1998,9(1):55-59.
  • 7Oshika T, Shiokawa Y, Amano S, et al. Influence of glistenings on the optical quality of acrylic foldable intraocular lens[J]. Br J Ophthalmol, 2001,85(9): 1034-1037.
  • 8Miranda Diez I,Gomez De Liano F,Vicente Ruiz A. Foldable Hydroview (H60m) intraocular lens: functional results and postoperative findings[J]. Arch Soc Esp Ophthalmol, 2000,75(1):35-42.
  • 9Dick HB,Tehrani M,Aliyeva S. Contrast sensitivity after implantation of toric iris-claw lenses in phakic eyes[J]. J Cataract Refract Surg, 2004,30(11):2284-2289.
  • 10Claoue C. Functional vision after cataract removal with multifocal and accommodating intraocular lens implantation:prospective comparative evaluation of Array multifocal and 1CU accommodating lenses[J]. J Cataract Refract Surg, 2004,30(10):2088-2091.

共引文献24

同被引文献132

引证文献9

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部