摘要
采用有功负荷作为制定初始恢复方案的依据,通过判断联络开关总备用容量与失电区总负荷的关系,确定是否需要提前转移二级支持馈线的负荷,以便扩大恢复供电的范围。采用广度优先搜索方法可使非故障失电区均匀恢复供电,且供电路径不会过长。引入了备用容量修正系数的概念,可根据电压(电流)过载情况,自动修正恢复方案。算例分析验证了该算法的可行性。
Taking active load as the fundamental to draw up initial service restoration scheme, by means of judging the relation between total reserve capacity of bus-tie circuit breakers and total load in power interruption region whether the load connected to the second supporting feeders should be shifted in advance is determined to enlarge the range of service restoration. Using breadth-first search algorithm that adopts the restoration of active load as the fundament for the design of initial restoration scheme, the power supply for the non-faulty interrupted region can be restored uniformly while the power supply path will not be too long. Leading in the concept of reserve capacity correction factor, the service restoration scheme can be automatically modified according to the overload condition of voltage or current. Analysis of case study verifies the feasibility of the proposed algorithm.
出处
《电网技术》
EI
CSCD
北大核心
2010年第7期103-108,共6页
Power System Technology
基金
国家自然科学基金资助项目(50807014)
电力系统及发电设备安全控制和仿真国家重点实验室开放课题(SKLD09KM08)资助~~
关键词
配电网
故障恢复
广度优先搜索
邻接表
备用
容量修正系数
distribution network
service restoration
breadth-first search
adjacent list
reserve capacity correctionfactor