期刊文献+

某8世代薄膜晶体管液晶显示器件(TFT-LCD)阵列厂房核心洁净区结构设计

CORE CLEAN AREA STRUCTURAL DESIGN OF THE 8^(Th) GENERATION TFT - LCD ARRAY - FACTORY
下载PDF
导出
摘要 某8世代薄膜晶体管液晶显示器件(TFT-LCD)阵列厂房为中国第一条8世代TFT-LCD生产线,核心洁净区建筑面积182 087.8m^2,为四层钢筋混凝土框排架结构,局部区域设置型钢柱间支撑,采用型钢混凝土柱。针对该工程特点,重点介绍了层间侧向刚度特别不规则的调整、地震作用下局部框架柱抗拉的解决方案、框架梁柱节点核芯区截面抗剪不足的处理、超长结构的防裂措施等。 With the core clean area of 182 087.8 m2 ,one of the 8TM Generation TFT-LCD array-factory is the first TFT-LCD production line. The building is a 4-floor concrete frame which has SRC post and steel column bracing set in some area. This paper presents the adjustment of the inter-story irregular lateral rigidity, the anti-seismic pull-resistance design of the posts,how to do with the joint core area shear-resistance insufficiency and the anti-crack methods of the ultra-long structural.
出处 《建筑技术开发》 2010年第7期12-15,39,共5页 Building Technology Development
关键词 层间侧向刚度 柱间支撑 型钢混凝土 钢纤维混凝土 超长 inter-story irregular lateral rigidity column bracing SRC steel fiber reinforced concrete ultra-long
  • 相关文献

参考文献3

  • 1建筑抗震设计规范(B50011-2001)[S].北京:中国建筑工业出版社,2008.
  • 2型钢混凝土组合结构技术规程(JGJ38-2001)[S].北京:中国建筑工业出版社,2002.
  • 3纤维混凝土结构技术规程(CECS38:2004)[S].北京:中国计划出版社,2004.