期刊文献+

武汉火车站多管相贯节点试验研究 被引量:6

Experiment Study on Multi-tube Intersection Joint of Wuhan Railway Station
下载PDF
导出
摘要 武汉火车站屋面结构采用正交正放的网壳结构,节点大多采用相贯节点,相贯节点的支管数目最多达8个,而且个别节点的主管与支管,支管与支管夹角较小,这些特点使节点区的焊接焊缝重叠较多,影响了节点的强度。通过多管相贯节点的单平面加载试验和有限元分析,证明多管相贯节点具有良好的工作性能;相贯节点在特定的加载方式下是安全的,并具有一定的安全储备。 Roof structure of Wuhan Railway Station adopts orthogonal spatial latticed shells structure with muhi-tube intersection joints, of which the maximum quantity of branch pipe is eight. Some joints have little angle between main pipe and branch pipe or between branch pipes. So there are many overlapping wielding in joint region which influence on joint' s strengthen. Plane load experiment of multi-tube intersection joint and finite element analysis prove that multi-tube intersection joint has fine workability and it is safe under special loading mode and has more safety.
出处 《施工技术》 CAS 北大核心 2010年第7期7-9,12,共4页 Construction Technology
基金 国家科技支撑计划项目--建筑结构高效施工关键技术研究(2006BAJ01B04-05)
关键词 武汉火车站 节点 相贯节点 试验 Wuhan Railway Station joint multi-tube intersection joint experiment
  • 相关文献

参考文献6

二级参考文献16

  • 1严慧,董石磷.板式橡胶支座节点的设计与应用研究[J].空间结构,1995,1(2):33-40. 被引量:40
  • 2刘建平.钢管相贯节点的承载力性能研究.清华大学硕士学位论文[M].,..
  • 3.(GBJ17—88).钢结构设计规范[S].,..
  • 4.网架结构设计与施工规程(JGJ7—91)[M].中国建筑工业出版社,1991..
  • 5赵伯川 余绍友 钱若军.网架结构在玻璃制造车间中的应用[A]..第六届空间结构学术会议论文集[C].地震出版社,1992..
  • 6何家炎 孟祥武 陈道行等.翁福磷矿精矿仓屋盖网架[A]..第七届空间结构学术会议论文集[C].,1994..
  • 7孟祥武 万超.江西宜春体育馆异型网壳设计[A]..第八届空间结构学术会议论文集[C].,1997..
  • 8日本建筑学会.钢管构造设计施工指针同解说[M].丸善株式会社,1990..
  • 9ENV 1993-1-1 : 1992. Eurocode No. 3,Design of Steel Structures.
  • 10Packer J A,Henderson J E. Hollow structural sections connects and trusses---a design guide. Canadian Institute of Steel Construction,Universal Offset Limited Alliston, 1997.

共引文献76

同被引文献36

引证文献6

二级引证文献5