摘要
根据CPR1000核电厂的特点,对常规岛主给水泵设计输入进行了分析,指出应选择一回路最佳估算流量下的接口参数为设计输入,给水泵的流量裕量取值为5%、阻力裕量取值为10%能够满足电厂最大连续出力运行要求,并具有良好的经济性。
Based on the feature of CPR1000 nuclear power plant, the purpose of the paper is to analyze the design input and margin selection of main feedwater pump in turbine hall, and it is found that the interface parameters between nuclear island and conventional island under best estimate condition shall be used as input data for the selection calculation of main feedwater pump parameters, while the pump shall consider 5% margin for flow-rate and 10% margin for resistance calculation, the result of selection calcu- lation based on the above condition can fully meet the long term operation requirement, besides, from the point of view of investment, the result is also economical.
出处
《核电工程与技术》
2010年第2期12-15,共4页
Nuclear Power Engineering and Technology