期刊文献+

腐蚀物包裹尘土导致手机接触失效的研究 被引量:2

Analysis of Corrosion Products Trapping to Contact Failure in Mobile Phones
下载PDF
导出
摘要 失效手机故障触点表面污染物的微观探测表明,污染物中含有大量尘土以及腐蚀物。模型分析显示,腐蚀物包裹尘土时,触头容易在腐蚀物上爬坡导致高电阻。对浸涂NaC l溶液后再喷撒S iO2颗粒的试片进行温湿循环试验,试片表面的S iO2颗粒被腐蚀物包裹,微动试验时触头难以推开被包裹的颗粒,导致试片表面高电阻的周期性跳变。可见,污染物中的腐蚀物包裹尘土颗粒,致使连接器簧片微动时在腐蚀物上爬坡,是引起触点高电阻导致手机失效的重要原因。 Micro-investigation shows that plenty of dust particles and corrosion products were found in the contaminants on contact surface of failed mobile phones.According to the model of corrosion products trapping,the probe tends to climb up the dust particles trapped in corrosion products,which results in high contact resistance.Particles of SiO2 were scattered on the brass coupon that had immersed in the solution of NaCl.After the experimentation of temperature-humidity cycling,particles were trapped in the corrosion products.During the process of micro-motion,the probe assisted by the corrosion products had to climb up the particles,and fluctuated high resistance appeared.It is obvious that the climbing of the connector spring on the dust particles due to corrosion products trapping is an important reason for contact failure in mobile phones.
出处 《机电元件》 2010年第2期3-7,18,共6页 Electromechanical Components
基金 国家自然科学基金的资助(NO.50677004)
关键词 腐蚀物 尘土 包裹 接触电阻 corrosion products dust trapping contact resistance
  • 相关文献

参考文献8

  • 1Zhang Ji-gao,Gao Jin-chun and Feng Cui-feng.Adhesion and attaching of particles at the failed connector contacts[A].Proceedings of the 23rd International Conference on Electrical Contacts[C] Sendai,Japan.June 2006.192-196.
  • 2Zhang Ji-gao.Effect of Dust Contamination on Electric Contact Failure[A].Proceedings of the 53rd IEEE Holm Conference on Electrical Contacts[C].Pittsburgh,USA.Sept.2007.xxi-xxx.
  • 3Lin Xue-yan,Zhang Ji-gao.Dust corrosion[A].Proceedings of the 50th IEEE Holm Conference on Electric Contacts[C].Seattle,USA.Sept.2004.255-262.
  • 4贺占平 许良军.失效连接器表面的微动特性与冲击仿真模型探讨.振动工程学报,2006,19:44-48.
  • 5Liang Ya-nan,Zhang Ji-gao.Liu Jia-jun.Identification of inorganic compounds in dust collected in Beijing and their effects on electric contacts[A].Proceedings of the 43rd IEEE Holm Conference on Electrical Contacts[C].Philadelphia,USA.Oct.1997.315-327.
  • 6林雪燕.北京长途电话局方庄分局数字配线架连接器可靠性调查报告[Z].北京邮电大学科研处.1996.
  • 7Zhang Ji-gao,Xu Liang-jun,Gao Jin-chun and Feng Cui-feng.Further studies of the mechanical behavior of particles on electric contact failure[A].Proceedings of the 24th International Conference on Electrical Contacts[C].Saint-Malo,France.June 2008.284-289.
  • 8GB/T 2423.4-93,电工电子产品基本环境试验规程试验Db:交变湿热试验方法[S].国家技术监督局.1994.