摘要
本文报告一种新的矩形外固定器,1992年以来,治疗5例桡骨远端粉碎性骨折,经临床观察和随访,治疗结果较满意。外固定针固定在2~3掌骨和桡骨干上。根据需要,闭合复位后,可利用外固定器行加压或撑开固定,该固定器具有操作简单和固定牢固等优点。
In this paper,a new rectangular external fixator is reported.Since 1992,5 cases of comminuted fracture of the distal radius were treated with the fixator in clinical application.Treatment result was satisfactory by clinical observation and follow up.Fixation pins were placed in the 2 3 metacarpal and radial shaft.According to demands,the external fixator could be applied in compression or distraction after closed reduction.The advantages of the rectangular external fixator were a simple procedure and stable fixation.The fixator is suitable for distal comminuted fracture of the radius.
出处
《中国矫形外科杂志》
CAS
CSCD
1999年第2期87-89,共3页
Orthopedic Journal of China
关键词
外固定器
桡骨骨折
闭合复位
治疗
External fixator Fracture of radius Closed reduction.