期刊文献+

周围神经不同间隙动脉套接的比较 被引量:10

Comparison of Small Gap Artery Sleeve Bridging Anatomosis and End to end Suture in Peripheral Nerve Repair.
下载PDF
导出
摘要 将大鼠的腓总神经切断后,分成1~4mm4组不同间隙,将远端转位90°行动脉套桥接,另设原位缝接和远端转位90°直接缝合两对照组。10周后的结果显示原位缝接组的神经再生效果最佳,1~3mm间隙组效果明显优于转位90°直接缝合。 The authors compared the effect of 1mm 4mm artery sleeve bridging and end to end suture in repairing division in right common peroneal nerve of Wistar rats.Thirty rats were divided into 1mm,2mm,3mm and 4mm nerve gap with artery sleeve bridging and distal stump turned 90° and two control groups (C1)in situ epineurium suture,(C2)epineurium suture with distal stump turned 90°.The results at the 10 th week showed the in situ epineurium suture is still the best method.If the defect is larger or the tissue bed is not good or nerve structure was poorly defined,artery sleeve bridging anatomosis should be attempted at first.The gap should be within two times of nerve diameter.
出处 《中国矫形外科杂志》 CAS CSCD 1999年第2期115-117,共3页 Orthopedic Journal of China
基金 卫生部优秀中青年基金
关键词 周围神经 动脉套桥接 间隙长度 实验 Peripheral nerve Artery sleeve bredging Gap.