期刊文献+

用于人体藏毒检查的平板真双能透视成像系统 被引量:4

Plate Dual-energy Perspective Imaging System for Body-hidden Drug Inspection
下载PDF
导出
摘要 目的:研制一种用于检查人体体内或体表藏毒的基于X射线的平板真双能透视成像系统。方法:系统采用一个高压可以调节的X射线源,2次曝光(50kV/100kV)实现真双能检测,探测系统采用具有高空间分辨力(36lp/cm)、大图像宽容度(16bit)和相对医学透视检查辐射剂量低等特点的平板探测器(FPD)。结果:该系统结合平板探测器的高图像分辨率和图像动态范围,及真双能成像对物质的高分辨能力,可实现对体内藏毒的有效识别。结论:该系统成像快,易于做成防护,是一种适合在禁毒一线现场使用的新型的人体藏毒检查设备。 Objective To develop a X-ray-based plate dual-energy perspective imaging system for body-or body surface-hidden drugs inspection.Methods A X-ray source with a regulable high voltage was used,combined with double exposure(50kV/100kV),to perform double-energy inspection.FPD was selected as the detection system,which was gifted with high spatial resolution(36 lp/cm),high image tolerance(16 bit)and low radiation dose.Results FPD combined with dual-energy imaging could inspect body-hidden drugs effectively.Conclusion The plate dual-energy perspective imaging system for body-hidden drug inspection,with a high imaging speed and being easy to perform protection,is an ideal tool for on-the-spot body-hidden drug inspection.
出处 《医疗卫生装备》 CAS 2010年第7期7-8,共2页 Chinese Medical Equipment Journal
基金 公安部第三研究所所选科研项目(C09392)
关键词 平板探测器 X射线真双能透视 人体藏毒 禁毒 flat plate detector X-ray dual-energy perspective imaging body-hidden drug drug control
  • 相关文献

参考文献5

  • 1杨业有.人体内藏毒的X线诊断.中华现代影像学杂志,2008,5(5):451-452.
  • 2SHI X H. Improving Object Classification in X-ray Luggage Inspection[D]. Ph.D dissertation: Virginia Polytechnic Institute and State University, 2000 : 64-65.
  • 3刘保玄.非晶硅X线平板探测器数字影像系统[J].医疗装备,2001,14(1):7-8. 被引量:3
  • 4祁建伟,谢松城.数字X射线摄影探测器技术的比较[J].生物医学工程与临床,2001,5(2):103-105. 被引量:4
  • 5Kuhlman J E ,Collins J,Brooks G N,et al. Dual-energy subtraction chest radiography: what to look for beyond calcified nodules[J]. Radiographics ,2006,26( 1 ) :79-92.

二级参考文献10

共引文献4

同被引文献32

  • 1孙丽娜,原培新.基于双能量X射线透射技术的物质分类识别方法研究[J].CT理论与应用研究(中英文),2005,14(2):22-27. 被引量:11
  • 2周祖荣.体内藏毒X线表现多样性分析[J].放射学实践,2006,21(2):200-201. 被引量:5
  • 3吴州.世界毒品探测技术及装备综述——《俄罗斯反恐防爆技术与装备》系列文章之四[J].警察技术,2007(3):64-67. 被引量:3
  • 4William J. Baukus, X-ray Imaging for On-The-Body Contraband Detection, Presented to 16th Annual Security Technology Symposium & Exhibition, Session V: Technology Forum Focus Group II, Transportation Security Technologies and Tools, June 28, 2000.
  • 5伍玉萍,康普顿散射成像技术研究,硕士学位论文,东南大学电路与系统,2007:2-3.
  • 6G.A.Eieeman&Z.Karpas著,郭海成,曹树亚译,离子迁移谱(第二版),国防工业出版社,北京.2010:224-228.
  • 7Y Kyriakou, E Meyer, D Prell, et al..Empirical beam hardening correction (EBHC) for CT [J].Med Phys, 2010, 37(7): 5179-5187.
  • 8R E Alvarez, J A Seibert, S K Thompson.Comparison of dual-energy detector system performance [J].Med Phys, 2004, 31(3): 556-565.
  • 9J Peter Stonestrom, R Alvarez, A Macovski.A framework for spectral artifact corrections in X-ray CT [J].IEEE Transactions on Biomedical Engineering, 1981, 28(2): 128-141.
  • 10W A Kalender, W H Perman, J R Vetter, et al..Evaluation of a prototype dual-energy computed tomographic apparatus.I.phantom studies [J].Med Phys, 1986, 13(3): 334-339.

引证文献4

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部