纳氏试剂分光光度法测定室内环境空气中氨的测量结果不确定度评定 被引量:3

The Evaluation of Uncertainty in Measurement of Ammonia Nitrogen in Indoor Environment with Nessler's Reagent Spectrophotometry
下载PDF
导出
摘要 对纳氏试剂分光光度法测定室内环境空气中氨质量浓度的不确定度进行了全面评定。建立了纳氏试剂分光光度法测定室内环境空气中氨质量浓度的不确定度数学模型,系统分析了测量方法测定结果不确定度的各影响因素,量化了各影响因素的相对标准不确定度,并计算出测量方法合成标准不确定度,最后得出扩展不确定度。 The report was about evaluation of uncertainty in determination of ammonia nitrogen in indoor environment with Nessler's reagent spcctrophotometry'. Authors analysised various factors which effect uncertainty of measurement, with the mathematical model they got all values of them. Finally. combined standard uncertainty and expanded uncertainty were evaluated.
出处 《广东化工》 CAS 2010年第7期269-271,共3页 Guangdong Chemical Industry
关键词 不确定度评定 纳氏试剂 室内环境 uncertainty evaluation ammonia nitrogen Nessler's reagent indoor environment
  • 相关文献

参考文献5

  • 1HJ/T167-2004.室内环境空气质量监测技术规范[S]:9-11.
  • 2陈成仁.测量不确定度评定培训讲义[R].北京,2008.
  • 3国家质量技术监督局.《大气采样器检定规程》JJG956-2000[M].北京:中国计量出版社,2004,4.
  • 4国家质量监督检验检疫总局.《空盒气压表和空盒气压计检定规程》JJG272-2007[M].北京:中国计量出版社,2007,12.
  • 5北京市环境保护监测中心.环境监测测量不确定度评定[M].北京:中国计量出版社,2009,1.