摘要 为了给消化道内姿态和位置均不断变化的胶囊内窥镜提供能量,提出了一种基于电磁感应的无线能量传输系统。该系统以亥姆霍兹线圈作为体外发射线圈,在覆盖人体消化道区域内产生均匀交变磁场;以三维正交线圈作为体内接收线圈,在消化道中的不同位置、以不同姿态均获得较为稳定的能量。设计、实现了无线能量传输系统的体外发射装置和体内能量接收装置,并通过实验验证了系统的有效性。结果表明:当发射功率为25W时,在胶囊内窥镜位置和姿态任意变化的情况下,传输功率可达320mW以上。 In order to deliver power to the capsule endoscope,whose position and orientation are always changing when traveling along the alimentary tract,a wireless power transmission system based on electromagnetic coupling was proposed.The system is composed of Helmholtz transmitting coil and three-dimensional receiving coil. Helmholtz coil outside the body generates a uniform magnetic field covering the whole alimentary tract; three-dimensional coil inside retrieves stable power regardless of its position and orientation. The transmitter and receiver were designed and implemented,and the experiments validated the feasibility of the system. The results show that at least 320mW of usable power can be transmitted to capsule endoscope when its position and orientation are changing at random and the transmitting power is 25W.
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2010年第3期490-494,共5页 Journal of Biomedical Engineering
基金 国家"863"资助项目(2006AA04Z368)
关键词 无线能量传输 电磁感应 亥姆霍兹线圈 三维接收线圈 Wireless power transmission Electromagnetic coupling Helmholtz coil Three-dimensional receiving coil
  • 相关文献

参考文献10

  • 1IDDAN G, MERON G, GLUKHOVSKY A, et al. Wireless capsule endoscopy [J]. Nature, 2000, 405 (6785): 417-417.
  • 2DELVAUX M, GAY G. Capsule endoseopy: Technique and inclications [J]. Best Practice & Research in Clinical Gastroenterology, 2008, 22 (5):813-837.
  • 3SI P, HU A P, MALPAS S, et al. A frequency control method for regulating wireless power to implantable devices [J]. IEEE Transactions on Biomedical Circuits and Systems, 2008, 2 (1):22-29.
  • 4马官营,颜国正,何秀.基于电磁感应的消化道内微系统的无线供能[J].上海交通大学学报,2008,42(5):798-802. 被引量:17
  • 5陈月娥,朱艳英.利用MATLAB模拟亥姆霍兹线圈磁场分布[J].电子技术(上海),2008,0(1):134-136. 被引量:10
  • 6王世山,汲胜昌,李彦明.变压器束绞圆导线线圈中涡流损耗的研究[J].高电压技术,2003,29(5):7-10. 被引量:13
  • 7MIURA H, ARAI S, KAKUBARI Y, et al. Improvement of the transcutaneous energy transmission system utilizing ferrite cored coils for artificial hearts[J]. Ieee Transactions on Magnetics, 2006, 42 (10): 3578-3580.
  • 8孙跃,卓勇,苏玉刚,王智慧,唐春森.非接触电能传输系统拾取机构方向性分析[J].重庆大学学报(自然科学版),2007,30(4):87-90. 被引量:14
  • 9U.S. National Library of Medicine. The Visible Human Project. httpJ/www, nlm. nih. gov/research/visible.
  • 10International Commission on Non-Ionizing Radiation Protection. Guidelines for Limiting Exposure to Time-varying Electric, Magnetic and Electromagnetic Fields. http://www, icnirp. de/documents/emfgdl, pdf.

二级参考文献29

共引文献48

同被引文献36

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部