摘要
以深圳地铁1号线续建工程前海车辆段为例,对带有物业开发的地铁车辆段生产及辅助用房、盖下大空间的通风空调及防排烟设计进行了探讨,并给出了设计做法,指出了有待继续深入研究的问题。
Taking the continuative project of Qianhai Depot of Line One in Shenzhen underground railway as an example,discusses the design of ventilation,air conditioning and smoke control for the production and auxiliary buildings and the large space of the depot with over development of buildings,provides the designing methods and points out the issues needed to be further researched.
出处
《暖通空调》
北大核心
2010年第7期1-4,共4页
Heating Ventilating & Air Conditioning
关键词
上盖物业开发
地铁车辆段
通风
空调
防排烟
设计
over development of building
underground railway depot
ventilation
air conditioning
smoke control
design