摘要 通过实测,得到了长江上游流域不同地表水体的水温、水质特性基础数据。通过该流域某地表水地源热泵实际工程的运行测试,得到其夏季机组制冷性能系数为4.32,系统性能系数为3.02,表明地表水地源热泵系统在该流域应用具有节能效果。 Collects and analyses the measured data of water temperature and quality of different surface water bodies in the reaches.By measurement during operation of a surface water source heat pump system in the reaches,obtains that the coefficient of performance of the heat pump and the overall system is 4.32 and 3.02 respectively in summer.The data indicate that the surface water source heat pump system applied to the reaches has a good energy saving effect.
机构地区 重庆大学
出处 《暖通空调》 北大核心 2010年第7期112-117,共6页 Heating Ventilating & Air Conditioning
基金 国家"十一五"科技支撑计划项目(编号:2006BAJ01A06-3)
关键词 长江上游流域 地表水地源热泵 水温 水质 性能系数 Yangtze River upper reaches surface water source heat pump water temperature water quality coefficient of performance
  • 相关文献

参考文献6

  • 1ASHRAE.地源热泵工程技术指南[M].徐伟,路宾,邹瑜,等,译.北京:中国建筑工业出版社,2001
  • 2王子云,付祥钊,王勇,仝庆贵.重庆市发展长江水源热泵的水源概况分析[J].重庆建筑大学学报,2008,30(1):92-94. 被引量:26
  • 3中国有色工程设计研究总院.GB 50019-2003 采暖通风与空气调节设计规范[S].北京:中国计划出版社,2004
  • 4中国建筑科学研究院.GB 50366-209 地源热泵系统工程技术规范[S].北京:中国建筑工业出版社,2009.
  • 5陈晓,张国强,彭建国,林宣军,林汉柱.开式地表水源热泵在湖南某人工湖的应用研究[J].制冷学报,2006,27(3):10-13. 被引量:23
  • 6中华人民共和国财政部办公厅,中华人民共和同住房和城乡建设部办公厅.关于组织申报2008年可再生能源建筑应用示范项目的通知(财办建[2008]64号)[EB/OL].[2008-06-07].http://www.mohurd.gov.cn/zcfg/jswj/jskj/200806/t20080604_170822 htm.