期刊文献+

污堵超滤膜元件的离线清洗和日常维护 被引量:1

Off line cleaning and maintenance overhaul for deposit block up of ultrafiltration membranes element
下载PDF
导出
摘要 华电新乡发电有限公司水处理预处理系统采用超滤净化工艺,系统运行2年后,超滤系统出现压差升高,出水量减少的现象,经过多次试验分析,最终找出了超滤污染的原因,经过离线清洗,并制定了保证安全运行的措施,彻底解决了困扰超滤出水的问题。 The ultrafiltration membrane was employed in Huadian Xinxiang Power Corporation Limited. After 2 years, it appeared the pressure increase and flux decline. The reasons were found out by experimental analyse. The flux problem were solved by off line cleaning and making safety measures.
作者 王绪文
出处 《清洗世界》 CAS 2010年第7期5-11,共7页 Cleaning World
关键词 超滤 膜分离法 实验分析 清洗 日常维护 uhrafihration membrane separation process experimental analyse cleaning maintenance overhaul
  • 相关文献

参考文献3

  • 1王爱兵,李雅,李淑贤,马子川,刘树明,王学才.超滤过程中膜污染控制和膜清洗的研究进展[J].河北工程大学学报(自然科学版),2009,26(2):98-102. 被引量:23
  • 2TRAN T, BOLTO B, GRAY S, et al. An autopsy study of a fouled reverse osmosis membrane element used in a brackish water treatment plant [ J ]. Water Research, 2007,41 ( 7 ) : 3917 - 3923.
  • 3中华人民共和国国家发展和改革委员会.DL/Z952-2005火力发电厂超滤水处理装置验收导则[S].北京:中国标准出版社,2005.