华电新乡发电有限公司水处理预处理系统采用超滤净化工艺,系统运行2年后,超滤系统出现压差升高,出水量减少的现象,经过多次试验分析,最终找出了超滤污染的原因,经过离线清洗,并制定了保证安全运行的措施,彻底解决了困扰超滤出水的问题。
The ultrafiltration membrane was employed in Huadian Xinxiang Power Corporation Limited. After 2 years, it appeared the pressure increase and flux decline. The reasons were found out by experimental analyse. The flux problem were solved by off line cleaning and making safety measures.
出处
《清洗世界》
CAS
2010年第7期5-11,共7页
Cleaning World
关键词
超滤
膜分离法
实验分析
清洗
日常维护
uhrafihration
membrane separation process
experimental analyse
cleaning
maintenance overhaul