摘要
研制了基于石英晶体微天平方法的聚醚酰亚胺湿度传感器,研究了它对相对湿度的响应特性和灵敏度以及这种湿度传感器在高湿度对比下的循环特性和长期老化性能。结果表明:在较宽的湿度范围内,这种湿度传感器表现出良好的湿敏特性。当相对湿度从11%变化至95%时,频率变化达2000Hz。高湿度差对比下的响应时间和恢复时间分别为30和20s。在循环测试和长时间老化测试中,也表现出优良的重复性和稳定性。
A novel type of humidity sensor was developed based on the quartz crystal microbalance coated with Polyethyleneimine (PEI).Its various aspects,such as its relative humidity (RH) response characteristics,its sensitivity,its cyclic characteristics at a fairly high relative humidity contrast,and its long-term aging performance,were experimentally evaluated.The results show that the PEI coated humidity sensor works pretty well in a wide range of humidity.In addition,as the relative humidity varies from 11% to 95%,its frequency shift is 2,000 Hz,and at an abrupt change in the relative humidity,the response and recover times of the sensor were found to be about 30 and 20 s,respectively.The many strengths of the newly-developed sensor include high sensitivity,good reproducibility,and satisfactory stability in cycling and aging tests.
出处
《真空科学与技术学报》
EI
CAS
CSCD
北大核心
2010年第4期355-358,共4页
Chinese Journal of Vacuum Science and Technology
基金
上海市科委基金(09DZ1142102
0752nm016)