摘要 目的:建立离子色谱法测定注射用头孢他啶中碳酸钠的含量。方法:色谱柱为Ionpac CG12A,CS12A阳离子交换柱,淋洗液为18 mmoL·L^-1甲烷磺酸,CSRS-ULTRA4 mm自动抑制循环模式,抑制电流为60 mA,电导检测池温度为35℃;进样量为25μL。由钠离子标准工作曲线直接测得注射用头孢他啶中钠离子的浓度。结果:钠离子浓度在2-20 mg·L^-1范围内呈良好的线性关系(r=0.9992);平均回收率为100.6%(n=9)。结论:本方法简单、快速,可以用于注射用头孢他啶中碳酸钠含量的测定。 Objective:To establish an ion chromatography method for the determination of sodium carbonate in ceftazidime for injection.Method:The determination was performed on an Ionpac CS12A column(4 mm×250 mm)with an Ionpac CG12A guard column(4 mm×50 mm).The mobile phase was a mixture of 18 mmoL· L^-1 methylsulfonic acid.The flow rate was 1.0 mL·min-1.A conductivity detector and an CSRS suppressor were used.Results:The standard curve was linear over the range of 2-20 mg·L^-1(r=0.9992).The average recovery was 100.6%(n=9).Conclusion:The method is simple,accurate,and suitable for the determination of sodium carbonate in ceftazidime for injection.
出处 《药物分析杂志》 CAS CSCD 北大核心 2010年第7期1268-1270,共3页 Chinese Journal of Pharmaceutical Analysis
关键词 离子色谱 碳酸钠 注射用头孢他啶 ion chromatography sodium carbonate ceftazidime for injection
  • 相关文献

参考文献5

二级参考文献13

  • 1彭图治 王国顺.分析化学手册(第四分册)电化学分析[M].北京:化学工业出版社,1999.159.
  • 2中华人民共和国药典委员会,中华人民共和国药典.二部,2000年,172页
  • 3彭图治,分析化学手册.4(电化学分析),1999年,159页
  • 4Peterson J A,Risley D S.receptor antagonist, using evaporative light scattering detection[].Journal of Liquid Chromatography.1995
  • 5Barbosa J,Beltran J L,Sanz-Nebot V.lonization constants of reference materials in acetonitrile-water mixtures up to 70% (w/w)[].Analytica Chimica Acta.1994
  • 6Mourey T H,Oppenheimer L E.Principles of operation of an evaporative light-scattering detector for liquid chromatography[].Analytical Chemistry.1984
  • 7Gard S,Elfakir C,Dreux M.Characterization of sulfobutyl ether-β-cyclodextrins mixtures by anion-exchange chromatography using evaporative light scattering detection[].Journal of Chromatography A.2000
  • 8Guiochon G,Moysan A,Holley C.Influence of various parameters on the response factors of the evaporative light scattering detector for a number of non-volatile compounds[].Journal of Liquid Chromatography.1988
  • 9Bosch E,Bou P,Allemann H,et al.Retention of ionizable compounds on HPLC.pH scale in methanol-water and the pK and pH values of buffers[].Analytical Chemistry.1996
  • 10Espinosa S,Bosch E,Roses M.Retention of ionizable compounds on HPLC.5. pH scales and the retention of acids and bases with acetonitrile-water mobile phases[].Analytical Chemistry.2000

共引文献122

同被引文献128

引证文献8

二级引证文献62

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部