期刊文献+

过零穿越极性相关法测量高温烟气流速技术的研究 被引量:3

STUDY OF ZERO CROSSING POLARITY CORRELATION FOR VELOCITY MEASUREMENT OF HIGH TEMPERATURE FLUE GAS
下载PDF
导出
摘要 应用过零穿越极性相关方法测量管道内高温烟气流速的系统,采用单片微机及自行开发的扩展系统和过零穿越算法,对烟气流动噪声信号作极性相关处理,快速搜寻峰值对应的时延值,并据此求得烟气流动速度。试验表明该测量技术具有测量精度高、测量时间短、系统简单、可靠性强等优点,适用于工业现场进行在线测量。 A zero crossing polarity correlation measurement method is proposed for the velocity of high temperature flue gas in pipe.We developed an experimental system consisting of one chip microcomputer and its extended system and applied zero crossing algorithm to the flow noise of high temperature flue gas.A delay time corresponding to correlation peak is obtained through fast seeking and changed into the flow velocity.The experimental results demonstrate that the correlation technique is a prospective on line measurement method with high precision,short measuring time and commercially reliability.
出处 《中国电机工程学报》 EI CSCD 北大核心 1999年第3期11-13,45,共4页 Proceedings of the CSEE
基金 国家自然科学基金
关键词 高温 烟气流速 测量 过零穿越算法 Polarity correlation\ Zero crossing\ High temperature flue gas\ Flow velocity
  • 相关文献

参考文献4

  • 1金武 袁镇福 等.相关法高温烟气速度测量的研究.第五届全国高校工程热物理年会论文集[M].大连,1994,5..
  • 2金武,第五届全国高校工程热物理年会论文集,1994年,5页
  • 3徐苓安,相关流量测量技术,1988年
  • 4徐秉铮,信号分析与相关技术,1981年

同被引文献31

引证文献3

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部