摘要 参考国内外研究成果,分析了我国下一世纪可能要建设的特高压输电系统限制过电压、潜供电流的主要方法,以及限制后过电压、潜供电流的水平,并选择了MOA的参数。在此基础上,对特高压系统的主要变电设备(包括变压器、断路器、隔离开关、电抗器和MOA)和输电线路的绝缘水平提出了建议。 Consulting the domestic and foreign research results, this paper presents the methods of suppressing over voltage and seconary arc current on UHV power transmission system of China in the next century. It also gives the over voltage level and the secondary arc current level after using the suppressing methods and the parameters of MOA. This paper, based on above analyses and researches, suggests the insulation level of the main equipment on UHV system (including transformer, circuit breaker, disconnecting switch, reactor and MOA), which can be used as references to research and manufacture of UHV equipment and design of power substation and transmission line.
作者 谷定燮
出处 《中国电力》 CSCD 北大核心 1999年第4期65-68,共4页 Electric Power
关键词 特高压 过电压 绝缘配合 特高压输电系统 UHV overvoltage insulation coordiration
  • 相关文献

参考文献5

  • 1谷定燮,陆宠惠.日本特高压系统过电压和绝缘配合[J].中国电力,1998,31(11):67-69. 被引量:20
  • 2武汉高压研究所.特高压技术前期及基础研究报告[M].,1987..
  • 3武汉高压研究所.赴日考察特高压的资料[M].,1997..
  • 4亚历山大罗夫ГH.超高压送电线路的设计[M].北京:水利电力出版社,1987..
  • 5武汉高压研究所.我国特/超高压输电技术发展学术研讨会论文集[M].,1995..