摘要 广州石油化工总厂炼油厂脱硫装置干气吸收塔,由于硫化氢应力腐蚀,使用20年后,在焊缝及其热影响区产生了不少裂纹。1997年,对已知裂纹进行了处理,并根据CVDA—1984“压力容器缺陷评定规范”进行了安全评定。检修后投用一年多,未发现异常情况。 After dry gas absorber has been operated for 20 years,the weld and its heat afective zone of dry gas absorber in sulfur removal unit of Guangzhou petrochemical complex refinery appeared a numbers of crack caused by hydrogen sulfide stress corrosion.In 1997,the handling of known crack is carried on.On the basis of CVDA 1984 “pressure vessel defects evaluation code” safety evaluation is executed.After repair and operating for more than 1 year,the abnormal condition did not appeared.
出处 《石油化工设备技术》 CAS 1999年第1期26-29,共4页 Petrochemical Equipment Technology
关键词 吸收塔 裂纹 缺陷 安全评定 脱硫装置 干气 Absorber,Crack defect,Handling,Safety evaluation
  • 相关文献

参考文献3

  • 1冯素霞.压力容器检验[M].中国劳动出版社,1993..
  • 2-.JB741-73“钢制焊接容器技术条件”.钢制石油化工压力容器设计规定[M].化学工业出版社,1979..
  • 3廖景娱,洪锡钢,卢适如,曾彦华,舒海涛.干气吸收塔裂纹产生原因分析[J].压力容器,1998,15(4):65-68. 被引量:1