期刊文献+

准分子激光原位角膜磨镶术治疗近视临床研究 被引量:3

Clinical study on laser in-situ keratomileusis for the correction of myopia
下载PDF
导出
摘要 目的探讨准分子激光原位角膜磨镶术(LASIK)治疗近视的疗效。方法用准分子激光机和自动微型板层角膜刀对357眼进行LASIK术。在PRK参数基础上,根据患者的年龄、职业、近视度做适当调整,保留角膜厚度250μm以上。结果随访1年~2年,平均15月。屈光度矫正率:中低度组105.3%,高度组99%,超高度组86.4%,无严重并发症。结论LASIK适合治疗各种不同屈光度的近视,在超高度近视由于角膜厚度的限制,其疗效稍差。 Objective To evaluate the efficacy of laser in-situ keratomileusis (LASIK) for the correction of myopia. Methods LASIK was performed on 357 myopic eyes with the excimer laser and automated corneal shaper. Laser parameters were adjusted based on the original prameters for PRK according to the age,ocupation,and the degree of myopia. Multizone ablation was used and the residual corneal bed thickness was 250 microns or thicker. Results The patients were followed up for 1 to 2years (mean, 15 months). The achieved corrections were 105. 3% (low to moderate myopia group),99% (high myopia group),and 86 % (ultrahigh myopia group) of the attempted correction in each group respetively.No severe complications occurred in the present study. Conclusion LASIK is effective for all amount of myoipa. However, the correction is limited by the corneal thickness in ultra-high myopic eyes.
出处 《眼外伤职业眼病杂志》 北大核心 1999年第2期105-106,共2页 Journal of Injuries and Occupational Diseases of the Eye with Ophthalmic Surgeries
关键词 准分子激光 近视 角膜磨镶术 LASIK Cornea, Excimer laser, Myopia, Refractive surgery
  • 相关文献

参考文献2

二级参考文献2

共引文献34

同被引文献10

引证文献3

二级引证文献3

相关作者