期刊文献+

肌酐酶法测定的两点法 被引量:18

Automatic analysis of enzymatic colorimetry for creatinine assay
下载PDF
导出
摘要 建立了实用的肌酐酶法测定方法,通过实验将比色测定终点法改为两点法,使其适合自动分析,并节省工具酶。本法的线性为0~2749μmmol/L,精密度:手工操作,批内CV<3%,总CV<5%。三种分析仪的批内CV在0.34%~1.44%间,回收率99.66%~100.9%。本法(Y)和BM的试剂(X)比较:Y=0.973X+10.33μmol/L,r=0.9995。 A practical method of creatinine enzymatic estimation was established.This colorimetry was changed from end point assay to tow point assay by experiment so that one can used in automatic analysis and the tools enzymes were saved in reagent.Analysis index of this method:linerity was 0 ̄2749 μmol/L;total CV and within run CV were ≤5 0% and ≤3 0% respectively for manual,and within run were 0 34% ̄1 44% for three autoanalyzer,analytical recoveries were 99 66% ̄100 9%,correlation between results by this method(Y) and BM′s reagent(X) were Y=0 973X+10 33 μmol/L, r =0 9995.
出处 《临床检验杂志》 CAS CSCD 北大核心 1999年第2期71-73,共3页 Chinese Journal of Clinical Laboratory Science
关键词 肌酐 酶法 两点法 血清诊断 creatinine enzymatic method tow point assay