摘要
1988~1997年,对济宁市5所医院物体表面与工作人员手。消毒液、室内空气细菌污染情况进行了检测。以细菌总数未超标且未检出致病菌者为合格。加强管理后的1993~1997年与未加强管理时的1988~1992年相比,前两项的合格率有明显上升,而空气的合格率改善却不明显。
The status of contamination of surface of various articles, hands of staffs, disinfectant solution and indoor air was examined in 5 hospitals of Jining City in 1988~1992 and 1993~1997. The eligibility rate including total bacteria count without exceeding allowable limit and no pathogenic bacteria detected after strengthening administration in 1993~1997 was significantly increased for contamination status of various surfaces and hands of staffs as compared with that in 1988~1992, while improvement of eligibility rate of air was not significant.
出处
《中国消毒学杂志》
CAS
1999年第1期48-49,共2页
Chinese Journal of Disinfection
关键词
细菌污染
检测
医院消毒
examination of bacterial contamination contamination of surface of article contamination of disinfectant solution air pollution hospital disinfection