期刊文献+

粉末树脂过滤器压差过高的原因及解决方法 被引量:4

CAUSES LEADING TO RAPID INCREASE OF PRESSURE DIFFERENCE IN POWDEX AND SOLUTION METHOD THEREOF
下载PDF
导出
摘要 对影响粉末树脂覆盖过滤器运行阻力因素进行的理论分析表明,过滤器压差增加过快的主要原因是进水悬浮物含量高、小粒径粉末树脂的比例大以及滤元受到污染。对此,可进行有效的机组停用保护,控制小粒径粉末树脂的比例以及对受到污染的滤元直接予以更换或进行化学清洗。陕西某电厂2×600 MW机组实施上述措施后,粉末树脂覆盖过滤器运行压差和运行周期已能满足机组运行要求。 Theoritical analysis of affecting factors upon operational resistance in the Powdex shows that the main causes leading to rapid increase of pressure difference in the Powdex are as follows:the content of suspended matter in influent water is high,the proportion of small particle size in powdered resin is large,and the pollution of filtering elements.For this,some effective methods for shut-down equipment conservation can be utilized,the proportion of small particle size in the powdered resin being controlled within a reasonable range,the polluted filtering elements being chemically cleaned or replaced.After implementation of the above-memtioned measures onto 2×600 MW units in one power plant of Shaanxi Province,the pressure difference and periodic operation time of the powdex already can satisfy the requirements of units in operation.
出处 《热力发电》 CAS 北大核心 2010年第7期90-94,共5页 Thermal Power Generation
基金 华能集团公司2007年科技开发资助项目(HNKJ07-G13)
关键词 直接空冷机组 粉末树脂 覆盖过滤器 滤元 压差 悬浮物 污染 direct air-cooled unit powdered resin Powdex filtering element pressure difference suspended matter pollution
  • 相关文献

参考文献3

二级参考文献3

  • 1田文华 和慧勇.直接空冷机组凝结水精处理系统存在的问题及对策.热力发电,2008,37(4):94-97.
  • 2ASTM D4519- 94(2005),Standard Test Method for On- Line Determination of Anions and Carbon Dioxide in High Purity Water by Cation Exchange and Degassed Cation Conductivity[S].
  • 3Hitzel H,Conlin J B. Further results of condensate polishing with separate cation and anion exchangers in the direct air cooled power station Marimba of ESKOM[J]. VGB Kraftwerkstechnik, 1991,71(1):58 - 61.

共引文献12

同被引文献25

引证文献4

二级引证文献11