摘要
通过对市政供热管网与室内系统连接的三种方式的分析,得出采用混水装置能够使系统安全、舒适运行,解决了低温热水地面辐射供暖供回水温度要求的问题,为人们提供了更舒适的生活环境。
Through analysis of three connecting methods of municipal heat supply pipe network and indoor system,it concluded that water mixing equipment can make system safe and comfort running,which resolved low temperature hot water ground radiation heat supply backwater temperature requirement problem,and provided comfort living environment for human being.
出处
《山西建筑》
2010年第22期217-218,共2页
Shanxi Architecture
关键词
混水装置
低温热水地面辐射供暖
采暖系统
water mixing equipment
low temperature hot water ground radiation heat supply
heating system