期刊文献+

基于MSP430的植入式脑起搏器的研制

Research and Design of an Implantable Brain Pacemakers Based on MSP430
下载PDF
导出
摘要 介绍了一种微型化的植入式脑起搏器;以MSP430单片机为核心处理器,充分利用高性能的外围芯片,例如nRF905、TPS76030、MG-12232等,并结合单片机内部资源;从而使该系统具有精度高、性能好、体积小和功耗低等特点,满足了帕金森病患者的需求。 This paper introduced a miniaturized implantable brain pacemaker.The system uses MCU MSP430 as its core processor with high performance internal resources and peripheral chips,such as nRF905, TPS76030,LCM(Liquid Crystal Display Module) MG-12232 and so on;Thus the system has many advantages such as high precision,stable performance,small volume and low power dissipation and so on,and could meet the needs of a variety of patients suffered from Parkinson's disease(PD).
出处 《生物医学工程学进展》 CAS 2010年第2期68-72,共5页 Progress in Biomedical Engineering
关键词 深部脑刺激 脑起搏器 刺激脉冲发生器MSP430 NRF905 deep brain stimulation brain pacemakers impulse generator MSP430 nRF905
  • 相关文献

参考文献7

  • 1孙斌.帕金森病的现代观(一)[J].解放军保健医学杂志,2005,7(1):50-51. 被引量:7
  • 2郑国庆,蔡业峰,雒晓东,黄燕,黄培新.帕金森病的综合性治疗[J].中国临床康复,2002,6(15):2234-2235. 被引量:12
  • 3Fogelson N,Kuhn AA,Silberstein P,et al.Frequency dependent effects of subthalamic nucleus stimulation in Parkinson's disease[J].Neurosci Lett,2005,382(1-2):5-9.
  • 4O' Suilleabhain PE,Frawley W,Giller C,et al.Tremor response to polarity,voltage,pulse width and frequency of thalamic stimulation[J].Neurology,2003,60(5):786-790.
  • 5Standard LCD module MG12232-12.http://www.bonafide.com.hk/catalog/MG12232-12.pdf..
  • 6Single chip 433/868/815MHz Transceiver nRF905 data sheet[S].2004.
  • 7Low-Power 50-mA Low-Dropout Linear Regulators (TPS76030 datasheet).Texas Instrument.2001.